The DHD 01 is a multifunctional liquid diluter that dilutes concentrated chemicals and rinses with clean water separately. Dilution takes place via the Venturi system, and the desired amount of chemical to be mixed with water is defined by TIPs (dosing tips). Suitable for use in perishable areas in supermarkets, butcher shops, bakeries, restaurants and industrial kitchens, etc.
This is the Portuguese user manual for the TRON DHD 01, a multifunctional liquid diluter. The unit dilutes a concentrated chemical product and separately rinses with clean water; dilution takes place through a Venturi system, and the amount of chemical mixed with the water is set by dosing tips (TIPs). The manual states it is intended for perishables areas in supermarkets, butcher shops, bakeries, restaurants and industrial kitchens.
The document explains how the water entering the top of the device creates suction at the side nozzle connected by hose to the concentrated product, lists the items supplied in the box, and gives the technical sheet and the 180-day warranty terms. It also covers operating requirements (minimum 1 kgf/cm², recommended at least 2 kgf/cm², maximum 3 kgf/cm² water pressure), a typical dilution rate table by TIP color and pressure, dilution precautions, an installation diagram and a question-and-answer troubleshooting section. This manual is written in Portuguese.
| Dilution principle | Venturi system with dosing tips (TIPs) |
|---|---|
| Minimum water pressure | 1 Kgf/cm² |
| Recommended minimum water pressure | 2 kgf/cm² |
| Maximum water pressure | 3 Kgf/cm² |
| Dilution rate format | X parts water to 1 part concentrated product (X:1) |
| Crystal plastic hose, inner diameter | 1/2" - 2 mm wall |
| Chemical inlet hose, inner diameter | 5/16" - 2 mm wall |
| Warranty | 180 days from the sales invoice date |
Check that the water pressure is within the indicated parameters, that the opening valve is in the open position, and inspect the piping for any air inlet. A very viscous product or the simultaneous use of more than one diluter can also affect dilution.
The most common cause is clogging of the TIPs, the venturi and the check valve, which can come from chemical deposits from the solute or salts in the water. Inspect the external connectors for blockage points.
Confirm that the water supply is actually feeding the DHD, that the opening valve is open and that the ball valve is being properly actuated, and check the water inlet and outlet for clogging.
The dilution table is based on diluting water in water, so solutes with different viscosities can change the rate. Check water and solute flow, use one diluter at a time, and change the TIP or the operating pressure to adjust the rate.