The AD71B is a digital multimeter with high accuracy and high resolution. It can measure voltage, current, resistance, capacitance, frequency, temperature and duty cycle. It also has data storage and recall functions.


AD Instruments AD71B Digital Multimeter User Manual - cover page
Brand
ADInstruments
Category
multimeter
Document type
User Manual
Language
Spanish
Pages
73
File format
PDF
File size
1.4 MB
Published
29 November, 2023
Updated
29 November, 2023
MD5 checksum
5CED98056580929C4C04A68EEE67F8E0

About this manual

The AD Instruments AD71B is an auto-ranging digital multimeter with a 4 ½-digit display and 20,000 counts. It measures AC and DC voltage and current, resistance, capacitance, frequency, duty cycle, temperature, and 4–20 mA loop current, and also provides True RMS, AC+DC, data hold, and reading storage and recall.

The manual covers safety rules, meter controls and display, measurement procedures, use of the SEND function, configuration changes, general maintenance, fuse and battery replacement, and detailed accuracy specifications. This manual is written in Spanish.

What's inside

  • Antes de comenzar
  • Conociendo el equipo
  • Realización de medidas
  • Uso del almacenamiento, recuperación y envío de datos
  • Cambios de los ajustes por defecto
  • Mantenimiento
  • Especificaciones
  • Especificaciones de precisión
  • Medida de tensión
  • Medida de corriente

Specifications

Display4 ½ digits
Counts20,000
RangingAuto-ranging
Safety standardIEC 61010
Pollution degree2
Overvoltage categoryCAT III 1,000 V, CAT IV 600 V
InsulationDouble insulation
Battery9 V (NEDA 1604, 6F22, 006P)
Auto power-off time10, 20, or 30 minutes, or OFF
Backlight auto-off time10, 20, or 30 seconds, or OFF
Temperature probe rangeBelow 230 °C

Frequently asked questions

What measurements can the AD71B perform?

It measures AC and DC voltage and current, resistance, capacitance, frequency, duty cycle, temperature, and 4–20 mA loop current, plus continuity and diode tests.

What battery does the AD71B use?

It uses a 9 V battery of type NEDA 1604, 6F22, or 006P.

How long is the auto power-off time and can it be changed?

The default auto power-off time is 10 minutes, and the setup menu allows 10, 20, 30 minutes, or OFF.

What safety ratings apply to the meter?

The meter complies with IEC 61010 at pollution degree 2, rated CAT III 1,000 V and CAT IV 600 V, with double insulation.