This product is an analog weight transmitter with 4—20 mA, 0—20 mA, 0—10 V, 0—5 V, -10—10 V, -5—5 V output range.
This document is the Installation and User Manual for the Laumas TLE Analog Weight Transmitter. It provides instructions for installing the instrument on a DIN rail, connecting load cells, and configuring the device for various analog output types including 4÷20 mA and 0÷10 V.
The manual details technical specifications such as the 24-bit A/D converter, operating temperature range, and maximum cable lengths. It also covers electrical connections, RS485 serial communication protocols (Modbus RTU), instrument commissioning, and procedures for restoring factory values.
| Dimensions | 90x95x60 mm |
|---|---|
| Analog Output Resolution | 16 bit |
| A/D Converter | 24 bit |
| Max Conversions Per Second | 300 |
| Operating Temperature | -20°C +60°C |
| Storage Temperature | -30°C +80°C |
| Power Supply | 12/24 VDC ±10% |
The maximum cable length for RS485 is 1000 metres when using AWG24, shielded and twisted cables.
The insulation value between the shield and any other cell wire must be higher than 20 Mohm.
The instrument can support a maximum of 8 load cells in parallel if they are 350 ohm.