Glod CTS Series Single Phase Voltage Regulator User Manual

CTS series single-phase voltage regulators use phase-shift triggering to achieve voltage regulation in order to control voltage. Its output voltage range is generally 0-98% of the rated voltage. It has functions such as soft start, soft stop, current limiting, overcurrent protection, and overheat protection.


Glod CTS Series Single Phase Voltage Regulator User Manual - cover page
Brand
Glod
Category
Thyristor
Document type
User Manual
Language
Chinese
Pages
10
File format
PDF
File size
6 MB
Published
26 November, 2023
Updated
26 November, 2023
MD5 checksum
E3B19032A5A92832ACEA311CC6EBB72E

About this manual

This is the Chinese product manual (version 2020.09) for the CTS series single-phase AC voltage regulator (调压控制器) made by Jiangsu Glod Electrical Control Technology Co., Ltd. The regulator uses phase-shift triggering of a thyristor to adjust output voltage over roughly 0-98% of rated voltage, with soft start/soft stop of about 2-3 seconds, current limiting, over-current protection and over-temperature protection. Control can be set by manual potentiometer (2.2-4.7K) or by an automatic current signal (4-20mA) or voltage signal (1-5VDC, 2-10VDC), selectable without changing the main unit.

The manual covers pre-order notes, a product introduction and function list, model selection tables for the CTS-II and CTS-I heatsink types (220VAC, electric heating loads only), installation and operating precautions, panel indicators and control-board wiring diagrams, plus a section on the additional Z-CTS single-phase rectifier regulator for DC motor speed control. It ends with the after-sales service terms, a repair form and company contact details. This manual is written in Chinese.

What's inside

  • Pre-selection notes
  • Product introduction
  • Product functions
  • Model selection tables (CTS-II, CTS-I)
  • Installation and operating precautions
  • Panel description and wiring diagram
  • Control board wiring diagram
  • Z-CTS single-phase rectifier voltage regulator
  • After-sales service

Specifications

Input supply220VAC single phase
Output voltage range0 to 98% of rated voltage
Soft start / soft stop timeapprox. 2-3 seconds
Control accuracy0.3%
Manual control inputPotentiometer 2.2-4.7K
Automatic current control input4-20mA, input impedance 250Ω
Automatic voltage control input1-5VDC (30KΩ) or 2-10VDC (12KΩ)
Mains frequency50 Hz to 60 Hz, auto-detected
Over-temperature protection thresholdheatsink above 80°C cuts output
Minimum load current0.6A
Ambient temperature-20 to 65°C
Relative humidity15-75%RH, no condensation
CTS-II models (220VAC)CTS-II-7KW, CTS-II-11KW, CTS-II-17KW
CTS-I models (220VAC)CTS-I-22KW, CTS-I-28KW, CTS-I-33KW
Z-CTS modelsZ-CTS-15A, Z-CTS-25A, Z-CTS-50A

Frequently asked questions

What type of load is the CTS series regulator intended for?

The models listed are only for electric heating loads; rated current already includes a 15% overload margin.

Which control signal inputs can be selected?

4-20mA current control, 1-5VDC voltage control or 2-10VDC voltage control, chosen when ordering.

What happens if the heatsink gets too hot or the fan stops?

When the heatsink exceeds 80°C the regulator cuts all output and latches; the power must be switched off and the fan checked before restarting.

What is the minimum load current that can be used?

The load current must not be less than 0.6A, otherwise the SCR will not work properly.

Download PDF (6 MB)