The D50 series of diaphragm pumps from Chengdu Hilin Technology Co., Ltd. feature operating status indication, brushless motors, protection functions, modular connectors, etc.
The Hilintec D50 series diaphragm pump manual describes the product characteristics, speed control functions, protection features, technical parameters, model naming, and wiring for the basic remote-control, frequency speed-control, voltage speed-control, touch-control, and top-specification versions.
The document is intended for technical personnel involved in product development and includes performance and reliability parameters, configuration options, modular air fitting choices, alarm handling, three-dimensional diagrams, and product appearance references. This manual is written in Chinese.
| Rated voltage | 24 V DC (input requirement 24 V ±10%) |
|---|---|
| D50S load current | ≤0.65 A |
| D50S peak flow | ≥11 L/min |
| D50S average flow | ≥6.8 L/min |
| D50S relative vacuum | ≥45 -kPa |
| D50S maximum pressure | ≥85 kPa |
| D50L load current | ≤1.1 A |
| D50L peak flow | ≥15 L/min |
| D50L average flow | ≥10 L/min |
| D50L relative vacuum | ≥50 -kPa |
| D50L maximum pressure | ≥100 kPa |
| D50H load current | ≤1.5 A |
| D50H peak flow | ≥22 L/min |
| D50H average flow | ≥15 L/min |
| Pump head material | Reinforced nylon |
| Diaphragm and one-way valve material | EPDM |
| Motor type | BLDC |
| Weight | ≈550 g |
| Standard hose size for barb fitting | 7*13 mm soft tube |
| Quick-connect tube sizes | 6 mm and 8 mm outer diameter hard tube |
Frequency speed-control, voltage speed-control, and top-specification versions provide remote speed control through frequency or voltage signals, while the touch-control and top-specification versions also allow speed and start/stop control from the LCD touchscreen.
RS-485 serial communication is provided on the top-specification version, and a Modbus-based RS-485 protocol can be ordered for speed adjustment, start/stop control, and operating status monitoring.
The pump includes overheat, overload, undervoltage/overvoltage, and reverse-polarity protection.
When power is restored, the pump resumes running at the state it had when the power was lost, including the remembered speed and whether it was running.