Dell|EMC AX4-5 Fibre Channel Storage Arrays With Microsoft® Windows Server® Failover Clusters Hardware Installation and Troubleshooting Guide
This guide covers configuring Microsoft Windows Server failover clusters with Dell AX4-5 Fibre Channel storage arrays in direct-attached or SAN-attached configurations. It describes cluster hardware requirements, cabling, storage system setup, and failover cluster installation.
It also includes troubleshooting information, a cluster data form, and a zoning configuration form for documenting the cluster environment.
| Cluster nodes | Minimum of two identical Dell PowerEdge servers |
|---|---|
| HBA ports | Two Fibre Channel HBAs per node, unless an integrated or supported dual-port HBA is used |
| NICs | At least two NICs: one for the public network and one for the private network |
| Internal disk controller | One controller connected to at least two internal hard drives for each node |
| Cluster nodes (Windows Server 2003) | Maximum of eight nodes |
| Cluster nodes (Windows Server 2008) | Maximum of sixteen nodes |
| Fibre Channel speeds | 8 Gbps, 4 Gbps, and 2 Gbps |
| AX4-5 disk processor enclosure | 1 DPE with at least 4 and up to 12 hard drives |
| AX4-5 storage expansion | Up to 3 DAE with up to 12 hard drives each |
| Standby power supply | 1 required; second optional |
| Supported storage systems per cluster | One to four |
| Direct-attached PowerPath capability | Failover protection only, not load balancing |
A minimum of two nodes is required.
The DPE requires at least 4 and supports up to 12 hard drives.
No, one SPS is required and the second is optional.
No, it provides only failover protection, not load balancing.