This document describes how to install and use the Whirlpool LZ™ and EZ™ Series Bottle Filling Stations & Coolers.
This manual provides installation instructions for the Whirlpool LZ and EZ Series Bottle Filling Stations and Coolers. It details versatile installation configurations, including left-hand high/right-hand low and left-low/right-high setups, noting that basin assemblies may need to be changed for certain configurations. The document includes specific rough-in dimensions for water supply, waste outlets, and electrical connections.
| Water Supply Tube Size | 3/8 O.D. Unplated Copper Tube |
|---|---|
| Water Supply Shut-off Distance | 3 IN. (76mm) MAXIMUM OUT FROM WALL |
| Waste Outlet Size | 1-1/2" O.D. DRAIN STUB |
| Waste Outlet Distance | 2 IN. OUT FROM WALL |
| Electrical Supply Type | (3) WIRE RECESSED BOX DUPLEX OUTLET |
| Ventilation Clearance | 6" (152 mm) (MIN.) CLEARANCE FROM CABINET LOUVERS TO WALL |
| Mounting Bolt Size | 7/16 BOLT HOLES |
New installations must use a Ground Fault Circuit Interrupter (GFCI).
No, the 1-1/2" trap is not furnished.
Yes, the design allows installation either left-hand high and right-hand low or left-low and right high.