The EChart GAS Flow Computer Manual introduces the features and specifications of the EChart GAS Flow Computer.
This manual provides operation instructions for the EChart GAS 1 flow computer, designed for use in oil and gas industries such as refineries and chemical plants. The device handles measurement trains and optional auxiliary meters, supporting flow equations including API 14.3, ISO 5167, and AGA 7, as well as density calculations via AGA 8. This manual is written in Spanish.
| Voltage Range | 7-24 VDC |
|---|---|
| Power Consumption | 0.3 WATT |
| Operating Temperature | - 40 A 85 °C |
| Enclosure Rating | NEMA 4X CLASE 1 DIV. 1 |
| Screen Resolution | 64x128 PIXELS |
| Processor | 32-BIT MOTOROLA 68332 @ 16.7 MHz |
| Flash ROM | 4 MB |
| RAM | 2 MB |
| Pressure Range | 0 hasta 3626 PSIG |
| DP Range | 0 hasta 1000 pulgadas |
| Analog Output | 16-BITS |
| Digital Output Capacity | 0.25 AMPS |
The manual recommends applying 24 volts for the power supply.
It supports Nuevo API14.3, ISO 5167, Turbina (AGA7), Cono en V, Medidor Ranurado DP, and Medidor Verabar y Annubar.
The integrated Rosemount transmitter supports a pressure range up to 3626 PSIG.