TripleA WINGMAN Tool Changer System Quick Guide Version 1.2

TripleA robotics makes flexible automation possible and profitable for high mix and low volume production companies through Applicable, Adaptable and Affordable robotic tools.


TripleA WINGMAN Tool Changer System Quick Guide Version 1.2 - cover page
Brand
TripleA
Category
Industrial Robot
Document type
Quick Start Guide
Language
English
Pages
7
File format
PDF
File size
1011 KB
Published
22 November, 2023
Updated
22 November, 2023
MD5 checksum
563AACEA58979AFD8F9D7CF9AACD2FF9

About this manual

This quick guide from TripleA is for the WINGMAN Tool Changer System. It says that it only partly includes the safety information and that the full safety information is in the user guide, which must always be read, understood, and followed in full. The product may not be used in any way based only on the instructions in this quick guide.

The guide covers installation, manual use, automatic use, and waypoints. For installation, the tool changer robot part is bolted to the cobot arm and tool parts are bolted to the end-effectors. It also describes installing pneumatic and electrical connections and installing tool part holders. Manual use describes unlocked, pre-locked, and locked lever positions, while automatic use describes waypoints and safety steps before automatic tool changes.

What's inside

  • Safety
  • Installing
  • Manual use
  • Automatic use
  • WAYPOINTS W0 ENTER PATH
  • W1 DISENGAGED
  • W2 TOOL HOLDER
  • W3 PRE-LOCKED
  • W4 Locked position
  • W5 EXIT PATH

Specifications

Default distance between W2 and W312 mm

Frequently asked questions

What safety information applies to the WINGMAN Tool Changer System?

The quick guide only partly includes the safety information, and the full safety information is in the user guide that must be read, understood, and followed in full. The product may not be used based only on this quick guide.

What must be turned off before engaging or disengaging the tool changer?

All energy and control to the end-effector must be turned off before engaging or disengaging the tool changer. Failing to do so can cause serious injury and even death.

What does the quick guide say about waypoint W2?

W2 is the tool holder waypoint where the robot part, tool part, and tool part holder are fully engaged, and it is the reference waypoint for all other waypoints.

Download PDF (1011 KB)