Dell DSS 1510 system overview
This manual provides comprehensive instructions for the maintenance and repair of the Dell DSS 1510 rack server. It details the procedures for installing and removing various system components, including the system cover, cooling shroud, memory modules, hard drives, cooling fans, expansion cards, processors, heat sinks, power supply units, system battery, hard drive backplane, control panel, power interposer board, and system board. Safety instructions and recommended tools are also included.
| Processor | Intel Xeon EP E5-2600 v4, E5-2600 v3, E5-1600 v4, or E5-1600 v3 |
|---|---|
| Memory | DDR4 registered, ECC RDIMMs up to 512 GB |
| Expansion Bus | PCIe generation 1, 2 and 3 |
| Storage Controllers | PERC H330, PERC H730, and PERC H730P |
| Power Supply | 450 W AC Platinum or 550 W AC Platinum |
| System Battery | CR 2032 3.0-V lithium coin cell |
It supports 4 x 3.5-inch cabled hard drives with non-redundant PSU, 4 x 3.5-inch hot swappable hard drives with redundant PSU, or 8 x 2.5-inch hot swappable hard drives/SSDs with redundant PSU.
No, the expansion cards are not hot swappable.
The system supports DDR4 registered, Error Correcting Code (ECC) Spare Rank, Single Device Data Correction (SDDC) RDIMMs at 1866 MT/s, 2133 MT/s, or 2400 MT/s.