The Baumit Low Energy Building Facade External Insulation System Manual introduces the concept of low energy buildings and describes in detail how the Baumit Facade External Insulation System helps buildings achieve low energy targets.
This document presents Baumit's solution for low-energy building facades, focusing on the external insulation system as a core technology for energy efficiency. It explains the principles of passive building concepts, such as high thermal insulation, airtightness, and the elimination of thermal bridges, to achieve high indoor comfort with minimal energy consumption.
The text details the physical variables defining insulation materials, including thermal conductivity (lambda), thermal resistance (R), and heat transfer coefficient (K). It compares various materials like EPS, XPS, and mineral wool, highlighting their specific thermal properties and their role in reducing heat exchange between indoor and outdoor environments. This manual is written in Chinese.
| Wall U-value | 0.10-0.15W/(m2 K) |
|---|---|
| Window U-value | ≤0.8W/(m2 K) |
| Airtightness (n50) | ≤0.6h-1 |
The ideal indoor temperature range is between 19 and 22 degrees Celsius.
The recommended air humidity level is between 40% and 60%.
It raises the inner surface temperature of the wall, reducing the temperature difference with the room and preventing cold radiation.