Dayton Superior Anchoring Cements, Epoxy Grouts and Bonding Adhesives Guide Specification

This document describes Dayton Superior's anchoring cements, epoxy grouts and bonding adhesives, epoxy sprays, and bonding agents.


Dayton Superior Anchoring Cements, Epoxy Grouts and Bonding Adhesives Guide Specification - cover page
Brand
Dayton Superior
Category
Other
Document type
Product Leaflet
Language
English
Pages
8
File format
PDF
File size
80 KB
Published
19 November, 2023
Updated
19 November, 2023
MD5 checksum
778AC6BC44B8F8109280BA94717FF260

About this manual

This document is a guide specification prepared by Dayton Superior Corporation to assist design professionals in preparing specifications for anchoring cements, epoxy grouts, bonding adhesives, epoxy sprays, and bonding agents. It is designed to be used as a basis for project specifications or office master specifications, following the principles of the Construction Specifications Institute (CSI).

What's inside

  • General
  • Submittals
  • Delivery, Storage and Handling
  • Project Conditions
  • Anchoring Cement
  • Epoxy Adhesive
  • Epoxy Grout
  • Epoxy Reinforcing Spray
  • Bonding Agents
  • Execution

Specifications

Compressive Strength (3 hours)4100 psi (28.2 MPa)
Compressive Strength (28 days)6800 psi (46.9 MPa)
Bond Strength (7 days)2100 psi (14.5 MPa)
Tensile Strength (28 days)340 psi (2.3 MPa)
Compressive Strength (Epoxy Adhesive)10,600 psi (73 MPa)
Bond Strength (Epoxy Adhesive)3000 psi (20 MPa)
Modulus of Elasticity (Epoxy Adhesive)500,000 psi (3447 MPa)
Water Absorption (Epoxy Adhesive)0.9 percent
Compressive Strength (Epoxy Grout)12,500 psi (86.2 MPa)
Bond Strength (Epoxy Grout)2200 psi (15.2 MPa)
Compressive Strength (Bonding Agent)10,400 psi (71.7 MPa)
Bond Strength (Bonding Agent)3150 psi (21.7 MPa)

Frequently asked questions

What is the minimum temperature for applying anchoring cements?

Do not apply anchoring cements at temperatures below 40 degrees F (4 degrees C).

What is the minimum temperature for applying epoxies?

Do not apply epoxies at temperatures below 40 degrees F (4 degrees C).

What is the compressive strength of Ankertite Cement at 28 days?

The compressive strength of Ankertite Cement is 6800 psi (46.9 MPa) at 28 days.

Download PDF (80 KB)

More Dayton Superior Manuals


View all Dayton Superior manuals →