This document is about the user manual for a concrete mixer manufactured by London Machinery Inc.
This document serves as the Owners Manual for London Machinery Incorporated transit mixers. It emphasizes that the equipment is durable when maintained by competent personnel and advises keeping a service logbook in the vehicle cabin. The manual provides general operational information, such as ensuring the main pedestal valve is open before starting the truck engine and checking drum roller alignment after initial use. This manual is written in Spanish.
| Reducer Lubrication Type | EP SAE 80-90 multigrade |
|---|---|
| SKK Reducer Capacity | 17 L |
| ZF Reducer Capacity | 16 L |
| Front Pedestal Oil Change Interval | 50 hours |
| Front Pedestal Oil Type | Esso Rando HD32 |
| Grease Type | EP#2 Grasa Base Litio |
The oil should be changed every 100 hours of operation, or at least once a year.
If water is present, the oil will have a milky appearance.
The grease points, such as the boom and drum rollers, should be serviced weekly.