This document serves as the Owners Manual for London Machinery Incorporated transit mixers. It emphasizes that the equipment is durable when maintained by competent personnel and advises keeping a service logbook in the vehicle cabin. The manual provides general operational information, such as ensuring the main pedestal valve is open before starting the truck engine and checking drum roller alignment after initial use. This manual is written in Spanish.

What's inside

  • General Information
  • Reducer Connections
  • Oil-Lubrication Specifications
  • Grease Points and Specifications
  • Maintenance Inspection
  • Hydraulic System Checks
  • Lighting System
  • Drum Speed Verification

Specifications

Reducer Lubrication TypeEP SAE 80-90 multigrade
SKK Reducer Capacity17 L
ZF Reducer Capacity16 L
Front Pedestal Oil Change Interval50 hours
Front Pedestal Oil TypeEsso Rando HD32
Grease TypeEP#2 Grasa Base Litio

Frequently asked questions

When should the reducer oil be changed?

The oil should be changed every 100 hours of operation, or at least once a year.

What indicates water in the hydraulic system?

If water is present, the oil will have a milky appearance.

How often should the grease points be serviced?

The grease points, such as the boom and drum rollers, should be serviced weekly.