User Manual & Installation Instruction for Electro-Steam Generator Corp.'s S.S. LB-80 Steam Generator.
This document serves as the user manual and installation instruction for the S.S. LB-80 steam generator manufactured by Electro-Steam Generator Corp. It details the safety features, installation requirements, and operational sequences for the unit, which is built in accordance with the ASME miniature boiler code. The manual emphasizes the importance of reading all instructions before operating the device to prevent property damage or injury.
| Ambient Temperature Limit | 104°F or 40°C |
|---|---|
| Water Purity Range | 1 – 5.5 MEG OHM per CM |
| Water Temperature Range | 32°F – 140°F or 0°C – 60°C |
| Water Supply Pressure Range | 20PSI – 150PSI |
| Blow Down Frequency | At least twice a month |
| Probe Cleaning Frequency | At least 3-4 times a year |
Blow downs should be performed at least twice a month, preferably while the generator is still hot.
The water level probes should be cleaned at least 3-4 times a year to prevent malfunctions.
The ambient temperature around the unit must not exceed 104°F or 40°C.