Xantrex XPower Micro Inverter 75/175 Owner's Guide

The XPower Micro Inverter 75/175 is an advanced power electronics and control product for wind, solar, battery, fuel cell, microturbine, and backup power applications.


Xantrex XPower Micro Inverter 75/175 Owner's Guide - cover page
Brand
Xantrex
Category
Other Electronics
Document type
User Manual
Language
English
Pages
72
File format
PDF
File size
710 KB
Published
18 November, 2023
Updated
18 November, 2023
MD5 checksum
89202EB59F3F8CF151D756FAA5D00D67

About this manual

The Xantrex XPower Micro Inverter 75/175 is designed for 230 VAC/50 Hz systems and is intended for use in vehicles with 12 V DC accessory outlets. The guide warns users of shock hazards and heated surfaces, advising against opening the unit or exposing it to water. It specifies that the output is non-sinusoidal and lists incompatible equipment such as certain battery-operated products and battery chargers for power tools.

What's inside

  • Important Safety Information
  • Features
  • Operation
  • Troubleshooting
  • Specifications
  • Warranty and Return

Specifications

Output Voltage230 Vac at 50 Hz
Continuous AC Output Power (75W model)60 W
5 minutes AC Output Power (75W model)75 W
No Load Current Draw< 0.35 A
Under Voltage Shutdown10.5 Vdc
Over Voltage Shutdown15.5 Vdc
Apparent Power (75W model)60 VA
Power Factor0.5–1

Frequently asked questions

What is the output voltage of the XPower Micro Inverter 75/175?

The nominal output voltage is 230 Vac at 50 Hz.

Can I use this inverter with small battery-operated products like flashlights?

No, the output is non-sinusoidal, so it should not be used with small battery-operated products such as rechargeable flashlights.

What is the maximum temperature the inverter housing can reach?

The housing may become uncomfortably warm, reaching 65°C (150°F) under extended high power operation.

What is the under voltage shutdown threshold?

The inverter shuts down if the input voltage drops below 10.5 Vdc.