GB/T 28418-2012 Fundamental Technical Requirements for Soil Moisture-Monitoring Instruments

This document specifies the classification, technical requirements, test methods, inspection rules, marking and instruction manuals, packaging, transportation, storage, etc. of soil moisture (墒情) monitoring instrument products.


GB/T 28418-2012 Fundamental Technical Requirements for Soil Moisture-Monitoring Instruments - cover page
Category
Other
Document type
Other
Language
Chinese
Pages
11
File format
PDF
File size
360 KB
Published
18 November, 2023
Updated
18 November, 2023
MD5 checksum
F62F5CAF353E96ACBF4BBD79A63F2E8A

About this manual

This standard specifies the classification, technical requirements, test methods, inspection rules, marking and instruction manual, packaging, transport and storage for soil moisture (soil moisture condition) monitoring instruments. It applies to instruments used directly for soil moisture monitoring in water resources utilization, drought relief, water-cycle research and agricultural irrigation.

The requirements cover general requirements, appearance, operating environmental conditions, basic parameters, electrical performance, mechanical environmental adaptability and reliability. Test methods, inspection rules and related provisions are also included. This manual is written in Chinese.

What's inside

  • Scope
  • Normative references
  • Terms and definitions
  • Product classification
  • Requirements
  • Test methods
  • Inspection rules
  • Marking and instruction manual
  • Packaging, transport and storage

Specifications

Measurement range0~50% soil volumetric water content
Accuracy at 3%~10% water contentRelative error absolute value not greater than 5%
Accuracy at 15%~25% water contentRelative error absolute value not greater than 2.5%
Accuracy at 35%~45% water contentRelative error absolute value not greater than 5%
RepeatabilityNot greater than 2% (repeatability standard deviation)
Operating temperature-10 C to 55 C
Relative humidity95% at 40 C, no condensation
Power supplyDC; recommended 12 V and 24 V; normal operation within -15% to +20% of rated voltage
Signal outputDigital RS232, RS485 or SDI-12; analog 1 V~5 V or 4 mA~20 mA
Power consumptionWorking current generally not greater than 200 mA; standby current generally not greater than 1 mA
Vibration test10 Hz~150 Hz~10 Hz sweep at 2g acceleration
Free fall test30 cm vertical height
ReliabilityMean time between failures not less than 16000 h
Stable timeNot greater than 10 s for FDR, TDR and capacitance instruments

Frequently asked questions

What measurement range is specified for soil moisture-monitoring instruments?

The measurement range should preferably be 0~50% soil volumetric water content.

What operating temperature range is specified?

The instruments should work normally at temperatures from -10 C to 55 C.

What reliability requirement is specified?

The mean time between failures should be not less than 16000 h.

What power supply voltages are recommended?

DC power is used, with recommended voltages of 12 V and 24 V.

Download PDF (360 KB)