Roth EX BW V2 Solar Controller Manual for the Specialized Installer

This product is a solar controller for basic systems, thermosiphon systems and swimming pool systems.


Roth EX BW V2 Solar Controller Manual for the Specialized Installer - cover page
Brand
Roth
Category
Other Electronics
Document type
Installation Guide
Language
Spanish
Pages
35
File format
PDF
File size
2.9 MB
Published
18 November, 2023
Updated
18 November, 2023
MD5 checksum
751CB1284960C311416FA861686B4A40

About this manual

Roth EX BW V2 is a solar controller for small and medium solar heating systems, thermosiphon systems and pool heating. It includes two relays, including a high-power relay for an electric immersion heater up to 3.6 kW at 230 V~, plus a PWM output for high-efficiency pump speed control.

The controller supports five preconfigured basic systems and controls electric auxiliary heating by time and temperature. The manual covers installation, electrical connections, system overviews, operation, monitoring, commissioning, channel display, remote control and troubleshooting. This manual is written in Spanish.

What's inside

  • Installation
  • Electrical connections
  • System overview
  • Systems
  • Operation and function
  • System monitoring screen
  • Commissioning
  • Channel display
  • Fast heating
  • Remote control RCTT

Specifications

Temperature sensor inputs3 Pt1000 probes
Remote control input1 RCTT
Semiconductor relay output1 (1) A at 240 V~
High-power relay output16 (3) A at 240 V~
PWM output1 output
PWM frequency1000 Hz
PWM voltage10.5 V
Power supply100-240 V~ (50-60 Hz)
Standby consumption0.52 W
Ambient temperature0 to 40 °C
Protection ratingIP 20
Dimensions172 x 110 x 46 mm
Weight330 g

Frequently asked questions

What is the maximum power of the electric immersion heater?

The high-power relay can connect an electric heater up to 3.6 kW at 230 V~.

How many temperature probes can be connected?

The controller has three inputs for Pt1000 temperature probes.

What is the PWM frequency for pump speed control?

The PWM output operates at 1000 Hz.

How many preconfigured basic systems are available?

Five basic systems can be selected, including forced, thermosiphon and pool systems.

Download PDF (2.9 MB)