CADel PRINCE, KOBE, FENICE, SPARK, INDACO, GO and ECLIPSE 11 Pellet Stove Installation Manual

This document is about the PRINCE 11 - KOBE 11 - FENICE 11 PRINCE PLUS 11 - KOBE PLUS 11 - FENICE PLUS 11 SPARK 11- INDACO 11 - GO 11 - ECLIPSE 11 installation manual.


CADel PRINCE, KOBE, FENICE, SPARK, INDACO, GO and ECLIPSE 11 Pellet Stove Installation Manual - cover page
Brand
Cadel
Category
Heater
Document type
Installation Guide
Language
Spanish
Pages
39
File format
PDF
File size
1.5 MB
Published
17 November, 2023
Updated
17 November, 2023
MD5 checksum
5F4593F1EB1B0629CDEEC10D615FCC88

About this manual

This installer manual covers packaging, handling, and installation of CADEL PRINCE, KOBE, FENICE, SPARK, INDACO, GO, and ECLIPSE 11 pellet stoves. It describes smoke evacuation, combustion air, assembly, electrical connections, maintenance, troubleshooting, and technical data.

The manual includes installation examples, minimum distances, ducting data, and cleaning procedures for the smoke chamber, smoke passage, smoke extractor, and room fan. This manual is written in Spanish.

What's inside

  • Packaging and handling
  • Installation and smoke evacuation
  • Combustion air supply
  • Installation examples and duct lengths
  • Assembly and minimum distances
  • Hot air ducting
  • Electrical and thermostat connections
  • Extraordinary maintenance and cleaning
  • Troubleshooting
  • Technical data and characteristics

Specifications

Minimum vertical run from stove outlet to first change of direction1.5 m
Minimum vertical smoke duct length, 80 mm pipe1.5 m
Minimum vertical smoke duct length, 100 mm pipe2 m
Maximum smoke duct length with one joint, 80 mm pipe6.5 m
Maximum smoke duct length with one joint, 100 mm pipe10 m
Maximum smoke duct length with three joints, 80 mm pipe4.5 m
Maximum smoke duct length with three joints, 100 mm pipe8 m
Maximum number of 90-degree joints3
Maximum horizontal smoke duct run2 m
Installation above 1200 m altitudeNot permitted with 80 mm pipe; mandatory with 100 mm pipe
Minimum safety distance from flammable construction elements500 mm
Maximum horizontal connection to chimney2 m
Maximum 90-degree bends in smoke discharge path3

Frequently asked questions

What is the minimum vertical run from the stove outlet to the first change of direction?

At least 1.5 m.

How many 90-degree bends are allowed in the smoke discharge path?

No more than three.

What is the minimum safety distance from flammable construction elements?

500 mm.

Can more than one appliance be connected to the same smoke duct?

No, connecting more than one appliance to the same smoke duct is prohibited.