This document is the instruction manual for the NPK automatic lubrication system, which introduces the features and functions of the system.
The NPK Autolube system is designed to automatically supply grease to the mechanical hammer chuck, extending its life by reducing wear. The system utilizes a high-pressure pump driven by an electric motor to pump EP2 grease at low temperatures and activates every time the hammer is triggered. It consists of a pump assembly and adapter nozzles, with the lubrication line varying by the host machine.
The document details specifications for various pump models (G075 through G186), including output rates and reservoir sizes. It provides specific connection port information for numerous hammer models (e.g., PH2, GH2, E203, H3XA) and includes instructions for electrical connection, filling the grease line, and troubleshooting issues such as no output or intermittent output. This manual is written in Spanish.
| Voltage | 12 – 24 V DC |
|---|---|
| Current | 2A |
| Mounting Hole | 0.39 pulg. (10 mm) |
| Factory Escapement Valve Setting | 4500 psi (315 bar) |
The system is designed to pump EP2 grease of low viscosity at low temperatures.
Use a line with a maximum inner diameter of 1/4 inch.
Turn the output adjustment screw clockwise.