The Tricel Pumping Chamber is manufactured from high density polyethylene, offering low weight, high strength, corrosion resistance and ease of installation.
This document provides comprehensive engineering and installation guidance for Tricel Domestic & Light Commercial Pumping Chambers, specifically models TPCIE2600 and TPCIE4000. The chambers are manufactured from Sheet Moulding Compound (SMC) and are designed for use where gravity drainage is not possible, pumping effluent to higher levels such as main sewers or treatment plants. The standard configuration includes a Tricel 75 pump for treated effluent and a GRI 11 pump for raw sewage, with optional dual pump systems available.
| Nominal Capacity (TPCIE2600) | 2612 litres |
|---|---|
| Overall Length (TPCIE2600) | 1.6 m |
| Weight Empty (TPCIE2600) | 200 kg |
| Solids Handling Capacity | up to 35mm in diameter |
They are manufactured from Sheet Moulding Compound (SMC), which is a fiberglass-based compression moulding.
The chamber comes with a Tricel 75 pump for treated effluent and a GRI 11 pump for raw sewage.
Yes, they may be supplied with a backup pump that alternates with the primary pump using a flip flop control panel.