This document is an installation manual for the EVLunic Pedestal floor-mounted column. The main features of this product are that it is easy to install and can be adjusted as needed.
This document provides installation instructions for the EVLunic Pedestal floor-mounted column, available in three variants (V1, V2, and V3). The V1 model supports one wallbox, while the V2 and V3 models are designed for two wallboxes. Installation requires a concrete foundation with specific dimensions and reinforcement, as well as the use of specific Hilti compact dowels for anchoring.
| Weight (without wallbox) | 15.0 kg (V1/V2), 19.2 kg (V3) |
|---|---|
| Recommended load (Tension) | 4 kN per dowel |
| Drill-hole diameter | 10 mm |
| Drill-hole depth | 33 mm |
The enclosed Hilti HKD-ER compact dowels M8x30 must be used for anchoring.
No, the installation of the pedestal on asphalt is not permitted.