Watch Water TRAPPSORB Start-up and Operation Manual

TRAPPSORB™ is an advanced adsorbent made from manganese oxide and calcium oxide with a purity of over 99%.


Watch Water TRAPPSORB Start-up and Operation Manual - cover page
Brand
Watch Water
Category
Chemical products
Document type
User Manual
Language
Spanish
Pages
7
File format
PDF
File size
1 MB
Published
17 November, 2023
Updated
17 November, 2023
MD5 checksum
78D310406BAB2372E9254EF004F76BD6

About this manual

TRAPPSORB is an advanced adsorbent based on manganese oxide and calcium oxide with purity over 99%, used for commercial applications in the food and beverage industry. This Spanish manual covers start-up and operation of TRAPPSORB filtration systems.

It includes basic installation, system configuration, backwashing triggers and conditions, deep cleaning with OXYDES-P, filter refilling, disinfection with chlorinated water, and pretreatment requirements. This manual is written in Spanish.

What's inside

  • Basic Installation
  • Common Configuration
  • Backwashing
  • Operating Conditions
  • Deep Cleaning
  • Filter Refilling
  • Disinfection
  • Pretreatment

Specifications

Maximum operating temperature60°C (140°F)
Operating pressure3 to 10 bar
Feed water pH6 to 9
Empty bed contact time4 to 6 min
Maximum service velocity7.5 to 20 m/h
Backwash duration10 to 15 min

Frequently asked questions

When should the filter be backwashed due to pressure loss?

When pressure loss through TRAPPSORB increases by 0.5 to 0.7 bar (7 to 10 psi).

What is the maximum operating temperature for TRAPPSORB?

The maximum operating temperature is 60°C (140°F).

How much OXYDES-P is used for deep cleaning?

Apply 28 grams of OXYDES-P per cubic foot of TRAPPSORB, typically in a 1% solution.

Download PDF (1 MB)