Weber webertherm EIFS Exterior Insulation Finishing System Application Manual

The webertherm EIFS system is a multi-layer insulation system that is suitable for exterior cladding on both new and renovated buildings. The system uses EPS prefabricated boards for thermal insulation, which are then coated, meeting the need for facade renovation based on energy criteria.


Weber webertherm EIFS Exterior Insulation Finishing System Application Manual - cover page
Brand
Weber
Category
Industrial Supply
Document type
Installation Guide
Language
Spanish
Pages
10
File format
PDF
File size
1.6 MB
Published
17 November, 2023
Updated
17 November, 2023
MD5 checksum
300DBA1BB02506679CA12962213584AE

About this manual

The Weber webertherm EIFS is a multi-layer exterior insulation and finish system used for new construction and renovation. It consists of substrate, expanded polystyrene (EPS) boards, base coat, fiberglass reinforcement mesh, and acrylic finish coat, providing thermal insulation, energy savings, impact resistance, and a variety of finishes.

The manual details step-by-step installation: starting profile placement, EPS board adhesion and mechanical fixing, reinforcement profiles at openings, base coat application with mesh embedding, and final acrylic coating. It includes technical data such as material consumption rates, mesh specifications, fixing densities, and mixing ratios. This manual is written in Spanish.

What's inside

  • Componentes y soportes
  • Ventajas del sistema
  • Paso a paso: Arranque del sistema
  • Colocación de placas
  • Fijación mecánica
  • Refuerzos y perfilería en aberturas
  • Revestimiento gris y malla
  • Revestimiento acrílico coloreado

Specifications

EPS board density20 kg/m³
Fiberglass mesh aperture5x5 mm
Base coat coverage as leveling coat3 kg/m² (2-3 mm thickness)
Base coat coverage as adhesive10 kg/m² (notch trowel No. 6)
Minimum mechanical fixing density6 anchors per m²
Drip profile mesh specification6x6 mm aperture, 165 g/m²
Corner profile mesh specification4x4 mm aperture, 165 g/m²
Base coat mixing ratio1 part water to 4 parts base coat

Frequently asked questions

What is the minimum number of mechanical anchors required per square meter?

A minimum of 6 anchors per m² is required, increased for height, wind exposure, and building edges.

What is the required overlap for fiberglass mesh joints?

Mesh joints must overlap by at least 10 cm.

What is the mixing ratio for webertherm base coat?

Mix 1 part water with 4 parts base coat powder.

What application methods are recommended for the acrylic finish coat?

The acrylic finish can be applied with a metal trowel for smooth textures, a medium-nap roller for rolled textures, or a hopper gun with a medium nozzle and 35 psi compressor for projected textures.