Alife Vinyl Floors SPC Installation Guide

Alife Vinyl Floors Installation Guide – SPC 1 SPC Installation Guide


Alife Vinyl Floors SPC Installation Guide - cover page
Brand
Alife Vinyl Floors
Category
Other
Document type
Installation Guide
Language
French
Pages
5
File format
PDF
File size
164 KB
Published
17 November, 2023
Updated
17 November, 2023
MD5 checksum
B50E072B8B83D022B09D57BFC38C02A5

About this manual

This guide provides detailed instructions for installing Alife Vinyl Floors SPC flooring. It outlines the necessary tools, acceptable and unacceptable substrates, and specific requirements for moisture testing and substrate preparation to ensure a successful installation. This manual is written in French.

What's inside

  • Matériel requis
  • Sous-planchers acceptables
  • Test d'humidité
  • Niveaux de pH
  • Stockage et manutention
  • Préparation du sous-plancher
  • Début de l'installation
  • Assemblage des planches

Specifications

Maximum subfloor thickness for underlayment1.5 mm
Required expansion gap around walls1/4 inch
Required expansion gap for areas over 30x30 ft1/2 inch
Minimum end joint stagger for plank installation6 inches
Minimum end joint stagger for tile installation3 inches

Frequently asked questions

What is the maximum relative humidity allowed for concrete subfloors?

The relative humidity must not exceed 80% or 95% according to ASTM F2170.

Can underlayment be used with attached pad SPC flooring?

No, underlayment should not be used with products that have an attached pad.

What is the required pH range for concrete subfloors?

The pH on concrete subfloors must be between 7 and 9.