MESSKO BA3527161/02 BeTech Pointer Thermometer Operating Instructions

This manual describes the features and specifications of the MESSKO® BeTech pointer thermometer BA3527161/02 ZH.


MESSKO BA3527161/02 BeTech Pointer Thermometer Operating Instructions - cover page
Brand
Messko
Category
Temperature sensors
Document type
User Manual
Language
Chinese
Pages
24
File format
PDF
File size
4.3 MB
Published
17 November, 2023
Updated
17 November, 2023
MD5 checksum
00FDD65FB1A4C837677CACFFE972A144

About this manual

The MESSKO BeTech BA3527161/02 is a pointer thermometer designed for measuring oil and winding temperatures in power and distribution transformers, reactors, or similar equipment. It uses a liquid-filled capillary system with a Bourdon tube measuring element and can include up to five adjustable microswitches for alarm or control functions. Optional versions provide analog outputs (4–20 mA, 0–5 V DC, Pt100) for remote monitoring and SCADA integration.

Installation requires shock-proof mounting, careful capillary routing (minimum bend radius 25 mm, clamping every 400 mm, spiral diameter ≥200 mm), and proper sensor pocket filling (15% free space for oil expansion). Electrical connections follow provided wiring diagrams, with specific terminal assignments for microswitches and analog outputs. Calibration procedures cover both thermostatic and gradient adjustments using heating current or built-in matching resistors. This manual is written in Chinese.

What's inside

  • Safety
  • Product Specifications
  • Installation
  • Electrical Connection
  • Thermostatic Calibration
  • Gradient Calibration
  • Technical Data
  • Appendix: Dimensions
  • Appendix: Analog Outputs
  • Appendix: Wiring Diagrams

Frequently asked questions

What is the MESSKO BeTech pointer thermometer used for?

It measures the temperature of power and distribution transformers, reactors, or similar operating equipment.

How many adjustable microswitches can the thermometer have?

The thermometer can have up to five adjustable microswitches.

What is the minimum bending radius for the capillary tube?

The minimum bending radius is 25 mm.

What must be done with terminals 61, 62, and 63 during insulation testing?

Terminals 61, 62, and 63 must be shorted, and the test voltage must be increased gradually.