This document is a user manual for COMPAK KHP-15/190 ACS2 Type Air-source Heat Pump Water Heater.
COMPAK KHP-15/190 ACS2 Type is an air-source heat pump water heater. This owner's and installation manual covers safety information, parts names, basic operation principle, installation, trial running, operation, troubleshooting, maintenance and specifications.
The manual states that installation must be performed by a qualified person and that the unit requires reliable earthing. It also lists water system limits: minimum water pressure 0.15 MPa, maximum water pressure 1.0 MPa, water inlet temperature not lower than 6 °C, and maximum set water temperature 70 °C.
| Minimum water pressure | 0.15 MPa |
|---|---|
| Maximum water pressure | 1.0 MPa |
| Minimum water inlet temperature | 6 °C |
| Maximum set water temperature | 70 °C |
The minimum water pressure of the water transmission pipeline system is 0.15 MPa.
The maximum water pressure is 1.0 MPa.
The water inlet temperature of the equipment shall not be lower than 6 °C.
The maximum water temperature of the equipment can be set as 70 °C.