This document describes the installation and operation specifications for the SEALCO dual seal system. The system consists of a 6 gallon (23 liter) reservoir, a regulating valve, a check valve, a pressure gauge, a bimetallic thermometer and a relief valve to help control the pressure and temperature in the tank in order to perform thermal convection.
The SEALCO TR-CT is a 6-gallon (23-liter) stainless steel reservoir system for double mechanical seals that uses water as a barrier fluid by thermal convection. The manual covers the reservoir construction, components, installation position, filling and pressure checks, monitoring, and maintenance.
The reservoir is normally pressurized to 40 psig and is recommended for dirty, abrasive, polymerizing, non-lubricating, or vacuum sealing applications. It includes a regulator valve, check valve, pressure gauge, bimetallic thermometer, relief valve, and vent/drain valve. This manual is written in Spanish.
| Construction | Stainless steel 304, schedule 10 |
|---|---|
| Capacity | 6 gallons (23 liters) |
| Maximum working temperature | 100 °C |
| Maximum pressure | 300 psig |
| Connections | 1/2 NPT and 1 NPT |
| Finish | Electrostatic gray paint |
| Regulator valve | Stainless steel |
| Check valve | Stainless steel |
| Pressure gauge range | 0 to 100 psig |
| Thermometer range | -20 to 110 °C |
| Relief valve | Included |
| Vent and drain valve | Included |
| Normal barrier fluid pressure | 40 psig |
| Supply water pressure | Greater than 40 psig |
| Installation distance from pump shaft center to reservoir centerline | No greater than 1.0 m |
| Installation height from flange center to side inlet | 1.0 m maximum and 0.8 m minimum |
| Maintenance interval | Every 2 months |
The reservoir has a standard capacity of 6 gallons (23 liters).
The water barrier fluid in the reservoir should normally be pressurized to 40 psig.
Open the drain valve and allow water to evacuate until the thermometer reads 30 °C, then close the valve again.
Maintenance, including complete drainage and replacement of the barrier fluid, is recommended every 2 months.