Greyline LIT25 Level Indicating Transmitter User's Guide

The LIT25 is a level indicating transmitter with the following features: - Measuring range: 0-10 meters - Accuracy: ±0.25% FSR - Resolution: 0.01 meters - Output: 4-20mA - Power supply: 24VDC


Greyline LIT25 Level Indicating Transmitter User's Guide - cover page
Brand
Greyline
Category
Other
Document type
User Manual
Language
English
Pages
37
File format
PDF
File size
1 MB
Published
17 November, 2023
Updated
17 November, 2023
MD5 checksum
0533D07D811459E9AB5F7CB88D3F5EA8

About this manual

The Greyline LIT25 is a level indicating transmitter designed for distance measurement using ultrasonic sensors. It features a 4-digit LCD display and a 2-key calibration system to manage operating modes and functions.

The device supports various sensor options (PZ32T, PZ12T_F, PZ34, PZ34T_F) and provides outputs via an isolated 4-20mA loop and a signal relay for alarms such as level, echo loss, or temperature.

What's inside

  • QUICK BENCH TEST
  • CONNECTIONS
  • KEYPAD SYSTEM
  • MENU
  • CALIBRATION UNITS SELECTION
  • 4mA CALIBRATION
  • SIGNAL RELAY
  • DAMPING
  • ECHO LOSS RESPONSE
  • OUTPUT SIMULATION

Specifications

Accuracy±0.25% of Range or 2 mm (0.08")
Power Input100-130VAC 50/60Hz (Standard)
OutputIsolated 4-20mA, 1000 ohm load maximum
Enclosure RatingNEMA4X (IP 66)
Operating Temperature (Electronics)-13 to 140°F (-25 to 60°C)
Standard Sensor Range (PZ32T)32 ft. (10 m)

Frequently asked questions

How do I perform a quick bench test on the LIT25?

Connect the sensor and apply power; aim the sensor at a flat target 12 to 28 inches away and wait a few seconds for the distance to display.

What are the maximum and minimum calibration values?

The maximum value is 600 inches (1524 cm) and the minimum value is 8 inches (20.3 cm).

What happens if the keys are not used for 10 minutes?

The LIT25 will automatically return to NORMAL MODE.

Download PDF (1 MB)

More Greyline Manuals