The ETICA 2300 Hardware Service Manual provides information on the features, specifications, and installation instructions for the ETICA 2300 Weighing-Labelling Unit.
This document serves as a hardware service manual for the Mettler-Toledo ETICA 2300 weighing-labelling unit, intended for After Sales Support technicians. It provides detailed information on the product's general characteristics, including technical and metrological specifications, and describes the maintenance tasks most frequently carried out on the unit. The manual includes an official summary list of spare parts and sub-assemblies available from MT-LOG.
| Input Voltage | 230 V, 50-60 Hz |
|---|---|
| Operating Temperature Range | -10°C to +40°C |
| Relative Humidity | 5% to 85 % |
| Precision Class | Class III |
| Resolution | 3000 points |
| Weighing Cell Power Supply | 5.4 Volts to 10 Volts |
| Maximum Unit Price | 9999,99€ |
| Communication Interfaces | RS232, RS485, Ethernet, USB |
This document is intended for After Sales Support technicians working on all normal versions of Etica 2300.
No, the unit cannot be used for direct sale to the public.