MEGA.ES Genuine since 1940. This document contains the operation and maintenance instructions for workshop presses.
This manual provides comprehensive instructions for the installation, operation, and maintenance of MEGA.ES workshop presses. It covers safety guidelines, assembly procedures, and general usage instructions for various models including the K100, K100E, BMD-6, BDD-10, and CDK-100. The document emphasizes the importance of following safety protocols and using the correct tools for specific tasks. This manual is written in Spanish.
| Operating Pressure | 700 kg/cm2 |
|---|---|
| Oil Volume (BMD-6) | 6200 cm3 |
| Oil Volume (BDD-10) | 10000 cm3 |
| Air Pressure Supply | 6 to 8 BAR |
| Air Hose Diameter | 12mm (1/2") |
Use hydraulic oil, type HL or HM, with a maximum ISO kinematic viscosity grade of 30cSt at 40 ºC, or an Engler viscosity of 3 to 50º C.
Check if the discharge valve is open, purge the hydraulic circuit for air, refill the oil tank if empty, clean the circuit, or check for a deformed piston.
No, the press should never be used for applications that should not be carried out with a press; always use the appropriate tool for each specific task.