About this manual

This chapter provides general information for stormwater detention practices, including definitions of pre-developed and developed conditions and factors that can increase storm runoff.

It also states Iowa DNR permit conditions, a 100-year design storm unless otherwise required, release-rate requirements, allowed detention volume methods, and limitations on downstream stormwater runoff.

What's inside

  • General Information for Detention Practices
  • Introduction
  • Storm Detention Regulations
  • Conditions that Require an Iowa DNR Permit
  • Design Storm
  • Release Requirements
  • Detention Volume Methods
  • Limitation of Stormwater Runoff

Frequently asked questions

What design storm return frequency is used?

The design storm is the rainfall event having a return frequency of 100 years, unless higher frequencies are required by the Department of Natural Resources or the Jurisdiction.

Which watershed routing methods are allowed?

The modified rational method may be used for areas up to 5 acres; for larger areas, the Storage Indication or modified Puls method should be utilized.

Who should design stormwater detention facilities?

The developer, subdivider, or applicant should construct stormwater detention facilities designed by a Professional Engineer licensed in the State of Iowa that meets the criteria of this section.