The document provides installation and maintenance instructions for the VICTORIA PLUS SILENT swimming pool water pump.
This manual is for AstralPool Victoria Plus Silent swimming pool water pumps. It covers safety regulations, installation, assembly, piping, location and electrical installation.
The pumps are designed for pre-filtering and recirculating clean pool water at temperatures that do not exceed 35 °C. It also describes warnings during start-up, assembly and maintenance work.
| Maximum water temperature | 35 °C |
|---|---|
| Residual current device rating | not more than 30 mA |
| Maximum suction pressure differential above water level | 0.02 MPa |
| Suction pipe slope | slight 2% slope towards the pump |
| Installation zones | zones 1 or 2 |
The pumps are designed to work with clean water at temperatures that do not exceed 35 °C.
The pump must be protected by a residual current device with a rated residual operating current that does not exceed 30 mA.
Yes, if it is a self-priming pump and the pressure differential to the suction pipe is not higher than 0.02 MPa.
Fit the suction piping on a slight 2% slope towards the pump to avoid the formation of air pockets.