iODM T1 Finished Bluetooth Test Equipment User Manual

The iODM T1 Finished Bluetooth Test Equipment is a multifunctional, high-performance Bluetooth test equipment. It can test finished Bluetooth RF performance, one-to-two dual-station test automatic judgment of success/failure, compatible with Agilent N4010A/Anritsu MT8852/R&S CMU200/R&S CMW500 (test time within 20S), automatic saving of excel reports, iODM proprietary anti-virus technology, customized UI+automated software, multi-user, multi-project management more humane, ergonomic operating table, built-in UPS uninterruptible power supply and leakage protection plug.


iODM T1 Finished Bluetooth Test Equipment User Manual - cover page
Brand
iODM
Category
Test Set
Document type
User Manual
Language
Chinese
Pages
11
File format
PDF
File size
1.8 MB
Published
16 November, 2023
Updated
16 November, 2023
MD5 checksum
33EC23ED71308E02C619F712D387947F

About this manual

iODM T1 is finished Bluetooth test equipment from iODM. The manual describes hardware startup steps, software screens, project and RF/EDR test settings, report viewing and export, system upgrade, user settings, device information, and advanced settings.

It also lists supported RF test parameters and compatible instruments, including Agilent N4010A, Anritsu MT8852, R&S CMU200, and R&S CMW500, with a test time within 20 seconds. This manual is written in Chinese.

What's inside

  • Overview
  • Hardware description
  • Software description
  • Test standby interface
  • User login
  • System settings
  • RF test settings
  • EDR test settings
  • Report viewing
  • System upgrade

Specifications

Compatible test instrumentsAgilent N4010A, Anritsu MT8852, R&S CMU200, R&S CMW500
Test timeWithin 20 seconds
Workstation configurationOne-to-two dual workstations
Output power testSupported
Frequency offset testSupported
Modulation characteristics testSupported
Power control testSupported
Carrier drift testSupported
Maximum input level testSupported
Single-slot sensitivity testSupported
Multi-slot sensitivity testSupported
Built-in UPSIncluded

Frequently asked questions

How do I export test reports?

Insert a USB drive, select the reports to export, and click export report; all reports can also be exported at once.

Who can change system settings?

The password is kept by engineering staff; production line operators cannot log in or change configuration.

What does black instrument text mean?

Black text means the instrument is not activated; contact Xiaoniu Measurement and Control for activation, and it turns white after activation.

Is EDR testing used on the production line?

EDR testing is for R&D use and is not used on the production line.