This document is a manual for the installation, operation and maintenance of water pumps.
This manual covers Simer pre-charged pressure tanks and explains safety, general information, installation, standard tank replacement, bleeder orifices, adjusting tank pre-charge, flushing air, checking tank air charge, testing for bladder leakage, and product information.
The tanks are factory pre-charged to 40 PSI (276 kPa). The manual includes drawdown values at several pressure switch settings and a product table with maximum capacity, equivalent standard tank size, diameter, height, and discharge tapping for each model.
| Factory pre-charge pressure | 40 PSI (276 kPa) |
|---|---|
| Maximum system pressure | Less than 100 PSI (689 kPa) |
| Tank and pressure switch spacing | Not more than 10 ft (3 m) |
| Cover flange nut torque | 65 in-lbs maximum |
| HT7-01 maximum capacity | 6 US gal (23 L) |
| HT20-01 maximum capacity | 19 US gal (72 L) |
| VT14-04 maximum capacity | 14 US gal (53 L) |
| VT19-02 maximum capacity | 19 US gal (72 L) |
| VT20-04 maximum capacity | 19 US gal (72 L) |
| VT36-04 maximum capacity | 35 US gal (132 L) |
| VT52-04 maximum capacity | 50 US gal (189 L) |
| VT96-04 maximum capacity | 85 US gal (322 L) |
| VT99-02 maximum capacity | 119 US gal (450 L) |
The tanks are pre-charged to 40 PSI (276 kPa) at the factory.
The tank and pressure switch cannot be more than 10 ft (3 m) apart.
Drain the tank, release all air pressure, disconnect the piping, carefully invert or lay the tank on its side, and check whether water runs out of the valve.
Shut off power, drain the tank, check the air pressure with a tire gauge, and adjust it according to Chart 1.