Simer HT7, HT20, VT14, VT19, VT20, VT36, VT52, VT96, VT99 Pre-Charged Pressure Tank Owner's Manual

This document is a manual for the installation, operation and maintenance of water pumps.


Simer HT7, HT20, VT14, VT19, VT20, VT36, VT52, VT96, VT99 Pre-Charged Pressure Tank Owner's Manual - cover page
Brand
Simer
Category
Other products
Document type
User Manual
Language
English
Pages
23
File format
PDF
File size
1.1 MB
Published
16 November, 2023
Updated
16 November, 2023
MD5 checksum
B79C9E30338DDDFE0ED5D77DA97371BC

About this manual

This manual covers Simer pre-charged pressure tanks and explains safety, general information, installation, standard tank replacement, bleeder orifices, adjusting tank pre-charge, flushing air, checking tank air charge, testing for bladder leakage, and product information.

The tanks are factory pre-charged to 40 PSI (276 kPa). The manual includes drawdown values at several pressure switch settings and a product table with maximum capacity, equivalent standard tank size, diameter, height, and discharge tapping for each model.

What's inside

  • Safety
  • General Information
  • Installation
  • Standard Tank Replacement
  • Bleeder Orifices
  • Adjusting Tank Pre-charge
  • Flushing Air from System
  • Checking Tank Air Charge
  • Testing For Bladder Leakage
  • Product Information

Specifications

Factory pre-charge pressure40 PSI (276 kPa)
Maximum system pressureLess than 100 PSI (689 kPa)
Tank and pressure switch spacingNot more than 10 ft (3 m)
Cover flange nut torque65 in-lbs maximum
HT7-01 maximum capacity6 US gal (23 L)
HT20-01 maximum capacity19 US gal (72 L)
VT14-04 maximum capacity14 US gal (53 L)
VT19-02 maximum capacity19 US gal (72 L)
VT20-04 maximum capacity19 US gal (72 L)
VT36-04 maximum capacity35 US gal (132 L)
VT52-04 maximum capacity50 US gal (189 L)
VT96-04 maximum capacity85 US gal (322 L)
VT99-02 maximum capacity119 US gal (450 L)

Frequently asked questions

What is the factory pre-charge pressure of these tanks?

The tanks are pre-charged to 40 PSI (276 kPa) at the factory.

How far apart can the tank and pressure switch be?

The tank and pressure switch cannot be more than 10 ft (3 m) apart.

How can I check for a leaking bladder?

Drain the tank, release all air pressure, disconnect the piping, carefully invert or lay the tank on its side, and check whether water runs out of the valve.

What should I do if drawdown decreases significantly?

Shut off power, drain the tank, check the air pressure with a tire gauge, and adjust it according to Chart 1.

Download PDF (1.1 MB)