Cembre HT-TC026 Hydraulic Cutting Tool Operation and Maintenance Manual

The HT-TC026 hydraulic cutting tool is a portable hydraulic tool used for cutting rebar, bolts and other metal materials. It is light weight, easy to operate, fast cutting speed and high efficiency.


Cembre HT-TC026 Hydraulic Cutting Tool Operation and Maintenance Manual - cover page
Brand
Cembre
Category
Other products
Document type
User Manual
Language
English
Pages
28
File format
PDF
File size
544 KB
Published
16 November, 2023
Updated
16 November, 2023
MD5 checksum
85FDDD6120352B915C6AA52FB95BD9B0

About this manual

Cembre HT-TC026 is a hydraulic cutting tool for steel ropes and conductors with a maximum diameter of 25 mm. This manual covers safety warnings, operating steps, cleaning, storage, head rotation, and maintenance.

Maintenance sections describe purging air from the hydraulic circuit, checking and topping up oil every six months, and replacing the lower and upper blades. The tool has a rated operating pressure of 600 bar and dimensions of 382 x 129 mm.

What's inside

  • General characteristics
  • Instructions for use
  • Setting
  • Blade advancement
  • Cutting
  • Blade opening
  • Maintenance
  • Oil top up
  • Blade replacement
  • Storage

Specifications

Maximum cutting diameter25 mm
Rated operating pressure600 bar (8,700 psi)
Length382 mm (15.03 in.)
Width129 mm (5.1 in.)
Weight3.2 kg (7.1 lbs)
OilAGIP ARNICA 32 or SHELL TELLUS OIL TX 32 or equivalent
Canvas bag size430 x 155 mm (16.9 x 6.1 in.)
Canvas bag weight0.15 kg (0.33 lbs)

Frequently asked questions

What is the maximum cutting diameter of the HT-TC026?

The tool is suitable for cutting steel ropes and conductors with a maximum diameter of 25 mm.

What oil should be used in the HT-TC026?

Use AGIP ARNICA 32 or SHELL TELLUS OIL TX 32, or an equivalent oil.

How often should the oil level be checked?

The oil level should be checked every six months.

How is air purged from the hydraulic circuit?

Hold the tool upright, open the reservoir, operate the movable handle and release lever repeatedly, remove air from the reservoir, then refit the cap and handle.