AgraTronix HT-PRO Portable Hay Moisture Tester Operator's Manual

The AgraTronix HT-PRO™ Portable Hay Moisture Tester is a versatile and easy-to-use tool that quickly and accurately measures hay moisture content and temperature. The tester features a rugged, durable design that is ideal for use in farm, ranch, and other agricultural environments.


AgraTronix HT-PRO Portable Hay Moisture Tester Operator's Manual - cover page
Brand
agratronix
Category
Agricultural Machinery
Document type
User Manual
Language
English
Pages
12
File format
PDF
File size
556 KB
Published
16 November, 2023
Updated
16 November, 2023
MD5 checksum
6C96E790E8E88784625C345EE2262D0D

About this manual

The AgraTronix HT-PRO is a portable hay moisture tester that measures hay moisture from 8.0% to 45% and temperature from 32 to 225 F (0 to 99 C). It has no ON/OFF switch; pressing any button except Backlighting turns it on, and a 9-volt alkaline battery is required.

The manual explains testing variables and hints for bales and windrows, calibration with the calibration clip, battery replacement, care and maintenance, troubleshooting, and the one-year warranty. It recommends taking readings in at least five places and using the highest reading as a guideline.

What's inside

  • GENERAL OPERATING INSTRUCTIONS
  • OPERATING NOTES
  • TESTING VARIABLES
  • TESTING HINTS: IN THE BALE
  • TESTING HINTS: IN THE WINDROW
  • CALIBRATION CHECK (RE-CALIBRATION)
  • BATTERY
  • CARE AND MAINTENANCE
  • TROUBLESHOOTING
  • WARRANTY

Specifications

Moisture measurement range8.0% to 45%
Most accurate moisture range10% to 30%
Temperature measurement range32 to 225 F (0 to 99 C)
Battery9-volt alkaline
Calibration check reading24.8%
Warranty periodOne year from date of retail purchase

Frequently asked questions

What battery does the HT-PRO require?

It requires a 9-volt alkaline battery, and LOBAT appears when the battery is low.

How do I turn on the tester?

There is no ON/OFF switch; press any button except Backlighting.

How should moisture be tested in a bale?

Insert the probe into the tight side at a 45-degree angle, take readings in at least five places, and use the highest reading.

How is the tester recalibrated?

Clean the probe tip, hold it in air and press and hold the 4 button until it displays 00.0, then place the calibration clip on the tip and press and hold 4 until 24.8% displays.