消防应急照明灯具,具有自动月检及年检功能,在正常使用并在应急工作过程中没有放电到自动关断的状态下,灯具在通电48H后每隔30±2天会由主电工作状态自动转入应急工作状态并持续60S,然后自动恢复到主电工作状态,同时绿色指示灯进入慢闪状态。灯具持续主电工作每隔1年并在应急工作过程中没有放电到自动关断的状态下,自动由主电工作状态转入应急工作状态并持续至放电终止,然后自动恢复到主电工作状态,同时绿色指示灯进入快闪状态。
This installation guide is for WAC Lighting fire emergency lighting fixtures in series HG-ZLZD-E16WDLK33 and HG-ZLZD-E22WDLK33. It covers installation declarations, wiring, technical specifications, performance, and usage.
The guide also describes indicator lights, monthly and annual self-tests, precautions, battery and light source information, and routine maintenance. This manual is written in Chinese.
| Rated supply voltage | 220 V, 50 Hz |
|---|---|
| Light source | LED, DC 31-38 V |
| Standard | GB17945-2010 |
| Emergency luminous flux | >50 lm |
| Main power consumption (HG-ZLZD-E16WDLK33) | 16 W |
| Main power consumption (HG-ZLZD-E22WDLK33) | 22 W |
| IP rating | IP30 |
| Emergency operating time | 90 min |
| Battery (HG-ZLZD-E16WDLK33) | Li-ion 18650 2200 mAh 3.7 8.14 Wh |
| Battery (HG-ZLZD-E22WDLK33) | Li-ion 18650 2200 mAh 3.7 V 8.14 Wh |
Charge the battery for at least 24 hours before use.
It indicates the battery is not installed or poorly connected, the DC fuse is open, the battery is shorted or failed, or the charging circuit is shorted.
Replace it immediately.
Pressing it for less than 3 seconds simulates a mains power failure, 3-6 seconds enters monthly test mode, and more than 6 seconds enters annual test mode.