WMB LactoCorder T-T Milk Measuring Instrument Operating Manual

This document is the WMB LactoCorder T-T operating manual, which introduces the features and characteristics of the product.


WMB LactoCorder T-T Milk Measuring Instrument Operating Manual - cover page
Brand
WMB
Category
Other device
Document type
User Manual
Language
English
Pages
13
File format
PDF
File size
421 KB
Published
16 November, 2023
Updated
16 November, 2023
MD5 checksum
7D9E36D6A5E2E0EB729E530CB1DD2460

About this manual

The LactoCorder T-T is an electronic measuring instrument from WMB AG used to check the quality and quantity of animal milk. The operating manual introduces the device, its intended use, transport and safety notes, and explains how to set it up in the stable.

The document also covers test fluid for water tests, one-time settings via the service menu, milk-quantity calculation when measuring without emptying, lithium-ion battery management and possible errors with their solutions. It includes a section on transferring data to LactoPro.

What's inside

  • Introduction
  • Safety
  • Transport
  • Test fluid for water tests
  • Setting up the LC T-T in the stable
  • One-time settings
  • Calculation of the amount of milk when measured without emptying
  • Battery management
  • Possible errors and their solutions
  • Transfer of data to LactoPro

Specifications

BatteryLithium-ion, 4400 mAh
Protection ratingIP 64

Frequently asked questions

What is the LactoCorder T-T used for?

It is used only to check the quality and quantity of animal milk.

What type of battery does the LC T-T use?

It uses a lithium-ion battery with 4400 mAh, and the battery indicator shows its capacity state.

What should I do if the LC T-T displays 'Storage Online. Failed!'?

Replace the USB stick, because the LC T-T cannot correct a PC USB communication error itself.

How is the test fluid for water tests prepared?

Mix 45 ml Neoagrar with 15.75 kg water; the mixture should have a conductivity between 5.5 and 6.5 mS.