Pro50 is a digital AC/DC solenoid activator and multimeter with the following features: Test 24v output from the clock/controller; Activate any AC or DC Low Voltage Solenoid; Chatter any AC or DC Low Voltage Solenoid for lost valve locating; Send tone to identify wires; Measure AC or DC Voltage and Resistance.
The Armada Technologies Pro50 is a digital AC/DC solenoid activator and multimeter; the Pro50K kit adds a Pro210F advanced tone probe and a soft carrying case. The guide explains battery testing, the F1/F2/F3 functions for DC solenoids, tone tracing, and AC solenoids, plus use of the built-in digital multimeter.
It also gives safety warnings, maintenance information, product specifications, and a one-year limited warranty. English and Spanish instructions are included.
| Connections | Removable standard multimeter alligator leads, 24 inch, red and black, Cat IV, 600 V |
|---|---|
| Tone tracing transmit power | +6 dBm (600 ohms) |
| Line transmit frequency | 900 Hz alternating with 1050 Hz at a 2 Hz rate |
| Line voltage protection | 120 Vac or 120 Vdc |
| Battery type | Four (4) AA or LR6 cells |
| AC Solenoid Operation | 24 volts AC |
| DC Latching Solenoid Operation | +9 volt DC and -9 volt DC pulses, 40 milliseconds |
| Test Range | 3,000 feet (1 km) over 18 ga (1 mm) cable |
| Built-in Multimeter | Tests AC or DC to 40 volts and resistance from 0 to 40 kilohms, auto-ranging |
| Display | 0.5 x 2 inches (12 x 50 mm) LCD |
| Battery saving Timeout | 30 minutes |
| Operating Conditions | +32 to +120 degrees F (0 to +50 degrees C) |
| Unit Size | 7 x 3 x 1.5 inches (175 x 80 x 35 mm) |
| Weight including test leads | 8.5 ounces (240 g) without batteries |
Yes. The Pro50 functions include testing 24 V output from the clock/controller.
Both require four AA batteries each, inserted on the back of each unit.
Press either the left or right arrow key from the main menu, then press F1 for DC voltage, F2 for resistance, or F3 for AC voltage.
The Pro50 is designed for use on de-energized circuits only, and users should use caution around voltages above 30 V ac rms or 60 V dc.