Master Water Conditioning 30/40 Combination Units 268/742 Valve Installation and Operation Manual

The document is an installation and operation manual for 30/40 COMBINATION UNITS with the 268/742 Logix Control Valve. This product can adjust the hardness of water.


Master Water Conditioning 30/40 Combination Units 268/742 Valve Installation and Operation Manual - cover page
Brand
Master Water Conditioning
Category
Other
Document type
User Manual
Language
English
Pages
20
File format
PDF
File size
1.2 MB
Published
16 November, 2023
Updated
16 November, 2023
MD5 checksum
5AB390AD812B898331FC0CE11F2E1495

About this manual

This manual from Master Water Conditioning covers the 30/40 combination units built with the 268/742 Logix top-mount automatic control valve. It lists the model numbers FES-30T and FES-40T (iron filter and softener), NS-30T and NS-40T (pH control and softener), and TS-30T and TS-40T (dechlorination and softener), together with the shipping carton contents and the filter media supplied for each model.

Installation steps cover positioning the unit, tank loading and filling with media, attaching the Logix control valve and 268 bypass, service and drain piping, and electrical requirements. The manual also explains the Logix 742 timer settings, filling the combination unit with water, the final installation check, troubleshooting by symptom, cause and solution plus an error table, valve body parts lists, and the limited warranty terms.

What's inside

  • Model # and Packaging
  • Combination Unit Positioning
  • Combination Unit Tank Loading
  • Logix Control Valve Installation
  • Service and Drain Piping
  • System Schematic Piping Layout
  • Electrical Requirements
  • Brine Tank and Brine Tubing
  • Logix 742 Control Valve Timer Settings
  • Final Installation Check

Specifications

Maximum working water pressure100 psi
Control valve materialNon-corrosive Noryl
Inlet/outlet connections1" copper or PVC with gasket and nut
Drain connection3/4" NPT
Maximum drain line length30 feet
Maximum drain line height6 feet above the control valve
Electrical supply115V/60Hz properly grounded dedicated outlet
Maximum amperage5 amps
Control valve warrantyFive years
Tank warrantyTwelve years against rust, corrosion or bursting

Frequently asked questions

Which combination unit models are covered by this manual?

The FES-30T and FES-40T iron filter and softener units, the NS-30T and NS-40T pH control and softener units, and the TS-30T and TS-40T dechlorination and softener units.

What electrical supply does the unit require?

A properly grounded dedicated 115V/60Hz outlet, with a maximum amperage of 5 amps.

How do I start a manual regeneration?

Push the regeneration button on the controller down for 5 seconds to initiate a manual regeneration.

What are the limits for the drain line?

The drain line must not be longer than 30 feet and must not rise more than 6 feet above the control valve.