Stork Cooperheat Twin Heat Module 13004 Instruction and Operating Manual

The Stork Cooperheat Twin Heat module is used for control of pre and post weld heat treatment of pipework and weldments, using one or two 300A welding units as low voltage power sources.


Stork Cooperheat Twin Heat Module 13004 Instruction and Operating Manual - cover page
Brand
Stork Cooperheat
Category
Industrial Supply
Document type
User Manual
Language
English
Pages
14
File format
PDF
File size
186 KB
Published
16 November, 2023
Updated
16 November, 2023
MD5 checksum
792734A632F9D5586EE58CC37537F301

About this manual

The Stork Cooperheat Twin Heat Module 13004 is used for control of pre and post weld heat treatment of pipework and weldments, using one or two 300A welding units as low voltage power sources. Each circuit includes a 180A AC contactor controlled by a temperature controller, a heater circuit ON lamp, a twin thermocouple socket, two safe locking sockets for heating element connections, and a power on lamp.

This manual covers specifications, functions, pre-commissioning checks, installation and commissioning, general operation of components and operating instructions, temperature controller operation, maintenance, fault finding, replacement parts, and warranty.

What's inside

  • Specifications
  • Introduction
  • Functions
  • Pre commissioning checks
  • Installation and commissioning
  • General operation of components
  • General operating instructions
  • Temperature controller operating instructions
  • Maintenance
  • Fault finding

Specifications

ApplicationControl of pre and post weld heat treatment of pipework and weldments
Power sourceOne or two 300A welding units as low voltage power sources
Secondary current180A per output channel
Contactor180A AC contactor controlled by a temperature controller
Auxiliary fuses10A and 5A auxiliary fuses
Auxiliary supply sockets110V auxiliary input and output sockets

Frequently asked questions

What is the Twin Heat module used for?

It is used for control of pre and post weld heat treatment of pipework and weldments, using one or two 300A welding units as low voltage power sources.

What secondary current does each output channel provide?

Each output channel provides 180A secondary current.

What thermocouple type is normally supplied?

Type K thermocouple wire is normally supplied.

What voltage should be measured during commissioning?

Readings of approximately 85 volts should be obtained between the output camlok socket and 0V on the welding machine.