The Stork Cooperheat Twin Heat module is used for control of pre and post weld heat treatment of pipework and weldments, using one or two 300A welding units as low voltage power sources.
The Stork Cooperheat Twin Heat Module 13004 is used for control of pre and post weld heat treatment of pipework and weldments, using one or two 300A welding units as low voltage power sources. Each circuit includes a 180A AC contactor controlled by a temperature controller, a heater circuit ON lamp, a twin thermocouple socket, two safe locking sockets for heating element connections, and a power on lamp.
This manual covers specifications, functions, pre-commissioning checks, installation and commissioning, general operation of components and operating instructions, temperature controller operation, maintenance, fault finding, replacement parts, and warranty.
| Application | Control of pre and post weld heat treatment of pipework and weldments |
|---|---|
| Power source | One or two 300A welding units as low voltage power sources |
| Secondary current | 180A per output channel |
| Contactor | 180A AC contactor controlled by a temperature controller |
| Auxiliary fuses | 10A and 5A auxiliary fuses |
| Auxiliary supply sockets | 110V auxiliary input and output sockets |
It is used for control of pre and post weld heat treatment of pipework and weldments, using one or two 300A welding units as low voltage power sources.
Each output channel provides 180A secondary current.
Type K thermocouple wire is normally supplied.
Readings of approximately 85 volts should be obtained between the output camlok socket and 0V on the welding machine.