RECHNER KFI-1-...ETW Capacitive Level Measuring System Operating Instructions

The RECHNER Industrie-Elektronik GmbH KFI-1-.ETW is a capacitive level measuring system for analog measurement. The system features a wide measuring range of up to 10 meters, high accuracy of up to 0.5%, good stability不受环境因素影响, easy installation and simple maintenance.


RECHNER KFI-1-...ETW Capacitive Level Measuring System Operating Instructions - cover page
Brand
RECHNER
Category
Other products
Document type
User Manual
Language
English
Pages
56
File format
PDF
File size
735 KB
Published
16 November, 2023
Updated
16 November, 2023
MD5 checksum
87DC9036D3505B055A7510F2A1660813

About this manual

RECHNER KFI-1-...ETW is a capacitive level measuring system for analogue level measurement. The compact probe has integrated evaluation electronics and is based on a patented three-electrode measuring principle; measurement takes place between the measuring electrode in the probe and the metallic container wall or a counter electrode.

The manual covers general description, mounting, technical data and electrical connection, analogue output AOUT and adjustment conditions, adjustment philosophy, analogue MIN and MAX adjustment, factory reset and test mode. The measuring section must not be mounted in areas of container cross-section changes, and the container earth or counter electrode must be connected directly to the blue wire of the cable.

What's inside

  • Important Note
  • General Description
  • Mounting
  • Technical Data / Electrical Connection / EasyTeach chart
  • Analogue Output AOUT / Adjustment Conditions
  • Adjustment Philosophy
  • Adjustment Analogue MIN
  • Adjustment Analogue MAX
  • Factory Reset
  • Test mode

Specifications

Electrical design5-wire DC
Operating voltage15...30 V DC
Permissible ripplemax. 5 %
Load resistance≤ 400 Ω (≥ 2 kΩ)
Power consumptionmax. 0.9 W
Analogue output4...20 mA (0...10 V)
Ambient temperature-25...+70 °C
Ambient temperature with temperature buffer-25...+200 °C
LED displayGreen
Protection classIP 67
StandardEN 60947-5-2
Connection cable2 m, PVC, 5 x 0.34 mm²

Frequently asked questions

What supply voltage does the KFI-1-...ETW require?

The system operates from 15 to 30 V DC.

What analogue output does the sensor provide?

It provides a 4 to 20 mA analogue output, or 0 to 10 V on the voltage-output version.

How long does the sensor take to become ready after power is applied?

It needs 2 seconds after supply voltage is applied before it is ready for operation.

Can Analog Max be adjusted before Analog Min?

No; the full adjustment with Analog Max can only be set after Analog Min has been defined.