The ECR-18, ECR-18i and Shock-18 are electric fences used to protect commercial, residential and industrial areas. They can be installed on high walls and give intruders an electric shock of 0.5 J (ECR-18 and SHOCK-18) and 4 J (ECR-18i), which complies with the IEC 60335-2-76 standard, which allows a maximum shock of 5 J.
This manual describes the installation and operation of the JFL Alarmes ECR-18, ECR-18i and SHOCK-18 electric fence energizers used to protect commercial, residential and industrial areas.
It covers technical characteristics, maximum perimeter wiring lengths, external and internal parts, remote control and wireless sensor programming, output voltage programming, and installation and safety notes. This manual is written in Portuguese.
| Supply voltage | 127/220 V AC, 60 Hz; 12 V DC battery |
|---|---|
| Power consumption | 5 W (up to 10 W with discharged battery); 3.6 kWh/month |
| Battery charger voltage | 13.8 V DC +/- 10% |
| Open-circuit output voltage | 18000 V +/- 10% |
| Output pulse energy (ECR-18/SHOCK-18) | < 0.5 J |
| Output pulse energy (ECR-18i) | < 4 J |
| Output pulse duration | 100 s |
| Output pulse frequency | 1 Hz (60 pulses/minute) |
| Dimensions | 295 x 235 x 120 mm |
| Gross weight (without battery) | 1.2 kg |
| Output current with 500 ohm load | 2.8 A |
| Maximum siren output current | 400 mA |
| Maximum siren plus auxiliary output current | 500 mA |
| Recommended battery | 12 V DC / 7 Ah sealed (not included) |
| Capacitor | 5 µF/440 V AC (ECR-18/SHOCK-18); 40 µF/380 V AC (ECR-18i) |
| Maximum perimeter wiring length (ECR-18/SHOCK-18) | 1600 m |
| Maximum perimeter wiring length (ECR-18i, 0.6 mm wire) | 5000 m |
| Maximum perimeter wiring length (ECR-18i, 0.9 mm wire) | 8000 m |
| Maximum perimeter wiring length (ECR-18i, 1.2 mm wire) | 12000 m |
| Wireless memory positions | 32 |
| Wireless frequency | 433.92 MHz |
| Entry/exit time (SHOCK-18, jumper disconnected) | 60 seconds |
| Fuse | 2 A |
| Recommended minimum fence height | 2 m |
| Required isolator rating | at least 20 kV |
| Compliance | IEC 60335-2-76 |
The maximum perimeter wiring length is 1600 m.
Output pulse energy is less than 0.5 J for ECR-18/SHOCK-18 and less than 4 J for ECR-18i.
The energizer has 32 memory positions for JFL wireless sensors and/or remote controls.