JFL Alarmes ECR-18, ECR-18i and SHOCK-18 Electric Fence Energizer User Manual

The ECR-18, ECR-18i and Shock-18 are electric fences used to protect commercial, residential and industrial areas. They can be installed on high walls and give intruders an electric shock of 0.5 J (ECR-18 and SHOCK-18) and 4 J (ECR-18i), which complies with the IEC 60335-2-76 standard, which allows a maximum shock of 5 J.


JFL Alarmes ECR-18, ECR-18i and SHOCK-18 Electric Fence Energizer User Manual - cover page
Brand
JFL Alarmes
Category
Other Electronics
Document type
User Manual
Language
Portuguese
Pages
12
File format
PDF
File size
2.1 MB
Published
16 November, 2023
Updated
16 November, 2023
MD5 checksum
6A9AED2F44BA8520CB836E55CCBB93FA

About this manual

This manual describes the installation and operation of the JFL Alarmes ECR-18, ECR-18i and SHOCK-18 electric fence energizers used to protect commercial, residential and industrial areas.

It covers technical characteristics, maximum perimeter wiring lengths, external and internal parts, remote control and wireless sensor programming, output voltage programming, and installation and safety notes. This manual is written in Portuguese.

What's inside

  • Technical characteristics
  • Maximum perimeter wiring length
  • External parts description
  • Internal parts
  • Remote control and wireless sensor programming
  • Remote control key functions
  • Enable/disable arming/disarming beep
  • Output voltage programming
  • LIGA input operating mode

Specifications

Supply voltage127/220 V AC, 60 Hz; 12 V DC battery
Power consumption5 W (up to 10 W with discharged battery); 3.6 kWh/month
Battery charger voltage13.8 V DC +/- 10%
Open-circuit output voltage18000 V +/- 10%
Output pulse energy (ECR-18/SHOCK-18)< 0.5 J
Output pulse energy (ECR-18i)< 4 J
Output pulse duration100 s
Output pulse frequency1 Hz (60 pulses/minute)
Dimensions295 x 235 x 120 mm
Gross weight (without battery)1.2 kg
Output current with 500 ohm load2.8 A
Maximum siren output current400 mA
Maximum siren plus auxiliary output current500 mA
Recommended battery12 V DC / 7 Ah sealed (not included)
Capacitor5 µF/440 V AC (ECR-18/SHOCK-18); 40 µF/380 V AC (ECR-18i)
Maximum perimeter wiring length (ECR-18/SHOCK-18)1600 m
Maximum perimeter wiring length (ECR-18i, 0.6 mm wire)5000 m
Maximum perimeter wiring length (ECR-18i, 0.9 mm wire)8000 m
Maximum perimeter wiring length (ECR-18i, 1.2 mm wire)12000 m
Wireless memory positions32
Wireless frequency433.92 MHz
Entry/exit time (SHOCK-18, jumper disconnected)60 seconds
Fuse2 A
Recommended minimum fence height2 m
Required isolator ratingat least 20 kV
ComplianceIEC 60335-2-76

Frequently asked questions

What is the maximum perimeter wiring length for ECR-18 and SHOCK-18?

The maximum perimeter wiring length is 1600 m.

What output pulse energy do these energizers provide?

Output pulse energy is less than 0.5 J for ECR-18/SHOCK-18 and less than 4 J for ECR-18i.

How many wireless sensors or remote controls can be programmed?

The energizer has 32 memory positions for JFL wireless sensors and/or remote controls.

Download PDF (2.1 MB)