The SJ24 surface grinder operation manual introduces the installation, operation and maintenance of the grinder.
This operation manual covers the Jakobsen SJ24 surface grinder from Jakobsen Planslibemaskiner ApS in Vejle, Denmark. It provides instructions for uncrating, lifting, installation, leveling, cleaning, assembly, oil filling, electrical connections, and starting up the machine.
It also describes hydraulic table travel, table overtravel adjustment, and the optional over-the-wheel hydraulic dressing attachment. A test sheet and an electrical motor illustration are included at the end.
| Hydraulic oil tank capacity | approx. 45 litres |
|---|---|
| Lubricating oil tank capacity | approx. 3.0 litres |
| Hydraulic pressure | 32 kg/cm (460 lbs/sq.in) |
| Diamond feed increment | 0,05 mm |
The hydraulic oil tank holds approximately 45 litres.
The gauge pressure must be 32 kg/cm (460 lbs/sq.in).
No. The machine should not be lifted or moved by the saddle or table.
It is leveled using three leveling screws and two stay-bolts.