This document is an installation, care and use manual for EZOTL series versatile bi-level water coolers.
This manual provides installation instructions for the EZOTL8 series versatile bi-level water coolers, including models EZOTL8*1G, EZOTL8*2G, and EZOTL8*3G. It details rough-in requirements, hanger bracket installation, and electrical connections. The document emphasizes safety precautions, such as disconnecting power before servicing and using a Ground Fault Circuit Interrupter (GFCI) for new installations.
| Stream Height Factory Setting | 35 PSI |
|---|---|
| Electrical Supply | 3 Wire |
| Ventilation Clearance | 6 inches minimum |
New installations must use a Ground Fault Circuit Interrupter (GFCI).
Adjust the screw located on the left side below the push bar assembly; clockwise raises the stream and counter-clockwise lowers it.
Maintain a minimum of 6 inches (152 mm) clearance from the cabinet louvers to the wall.