About this manual

This owner's manual covers the VersaClean VersaTile VT1200 Hard Surface Cleaner, Model 67-039, a 120V unit from Legend Brands, Inc. It begins with safety and grounding instructions and identifies the controls and components, including the pressure pump, vacuum, pumpout, and solution controls.

The manual then describes before-first-use steps such as installing the handle and flushing the system lines, setup for hard surface cleaning with a faucet mounting kit, the starting procedure, normal and heavy-soil cleaning procedures, and transportation and storage. It also states that the pressure pump's break-in oil must be replaced after 50 hours with SAE 30W motor oil.

What's inside

  • Grounding Instructions
  • Additional Warnings and Notices
  • Before You Begin
  • Controls and Components
  • Before First Use
  • Setup for Hard Surface Cleaning
  • Starting Procedure
  • Cleaning Procedures
  • Transportation and Storage

Specifications

Model67-039
Voltage120V
Power circuit requirementTwo separate 15 amp 115V/60 Hz circuits
Cord requirement12 gauge or larger cords
Factory start-up pressure900–1000 psi
Target operating pressure950–1000 psi
Pressure pump break-in oil replacement interval50 hours
Replacement oilSAE 30W motor oil
Replacement oil quantity suppliedOne pint (0.5 l)

Frequently asked questions

What is the factory start-up pressure for the VT1200?

The VT1200 is set at the factory for a 900–1000 psi start-up pressure; 950–1000 psi is the target operating range.

What power supply does the unit require?

It must be plugged into two separate 15 amp 115V/60 Hz circuits.

When should the pressure pump oil be replaced?

The break-in oil must be replaced after 50 hours of use with SAE 30W motor oil.

What should be flushed before first use?

Flush internal lines with fresh water prior to use; the unit may contain residual antifreeze from the factory.