This is a versatile cleaning tool that can clean hard surfaces.
This owner's manual covers the VersaClean VersaTile VT1200 Hard Surface Cleaner, Model 67-039, a 120V unit from Legend Brands, Inc. It begins with safety and grounding instructions and identifies the controls and components, including the pressure pump, vacuum, pumpout, and solution controls.
The manual then describes before-first-use steps such as installing the handle and flushing the system lines, setup for hard surface cleaning with a faucet mounting kit, the starting procedure, normal and heavy-soil cleaning procedures, and transportation and storage. It also states that the pressure pump's break-in oil must be replaced after 50 hours with SAE 30W motor oil.
| Model | 67-039 |
|---|---|
| Voltage | 120V |
| Power circuit requirement | Two separate 15 amp 115V/60 Hz circuits |
| Cord requirement | 12 gauge or larger cords |
| Factory start-up pressure | 900–1000 psi |
| Target operating pressure | 950–1000 psi |
| Pressure pump break-in oil replacement interval | 50 hours |
| Replacement oil | SAE 30W motor oil |
| Replacement oil quantity supplied | One pint (0.5 l) |
The VT1200 is set at the factory for a 900–1000 psi start-up pressure; 950–1000 psi is the target operating range.
It must be plugged into two separate 15 amp 115V/60 Hz circuits.
The break-in oil must be replaced after 50 hours of use with SAE 30W motor oil.
Flush internal lines with fresh water prior to use; the unit may contain residual antifreeze from the factory.