Weber Lab Biosafety Level 2 Manual

This document is the Weber Lab Biosafety Level 2 Manual. It outlines the safety precautions that must be followed when working with Listeria in the Weber Lab.


Weber Lab Biosafety Level 2 Manual - cover page
Brand
Weber Lab
Document type
Other
Language
English
Pages
8
File format
PDF
File size
318 KB
Published
15 November, 2023
Updated
15 November, 2023
MD5 checksum
8A0763EDF206EDECFA1353FF3D825013

About this manual

This is the Weber lab Biosafety 2 Manual, dated 10/22/14. One of the lab's projects uses the Biosafety level 2 (BSL-2) pathogen Listeria monocytogenes, so every lab member must understand the necessary safety precautions and be trained in proper BSL-2 technique. Each member must read the manual, discuss it with Dr. Weber, and obtain his signature as a prerequisite for working in the laboratory. All BSL-2 work must be done in room 3126A LSB or the mouse room 1012B LSB. The manual states it has two parts: the biosafety level 2 standard practices the lab will follow (pages 6-9) and the Pathogen Safety Data Sheet for Listeria monocytogenes (pages 10-14).

The text sets out standard microbiological practices, special practices, and safety equipment requirements for BSL-2 work, including hand washing, restrictions on eating and drinking in lab areas, sharps handling, decontamination of work surfaces and cultures, posted biohazard signage, and the use of biological safety cabinets, protective clothing, eye protection, and gloves. It also lists restrictions: pregnant women, the elderly, and immune-compromised individuals will not work on the Listeria monocytogenes project as a precaution.

What's inside

  • Training and Signature Requirement
  • Restrictions
  • Biosafety Level 2 lab practices
  • Standard Microbiological Practices
  • Special Practices
  • Safety Equipment (Primary Barriers and Personal Protective Equipment)
  • Pathogen Safety Data Sheet for Listeria monocytogenes

Specifications

Biosafety levelBiosafety level 2 (BSL-2)
Pathogen handledListeria monocytogenes
Approved BSL-2 work locationsroom 3126A LSB or the mouse room 1012B LSB
Hood cleaning agents1:10 dilution of Lysol I.C. quaternary disinfectant cleaner and 95% ethanol
Listeria monocytogenes waste treatmentBleach (1:10 dilution) before disposal in biohazard containers
Flow cytometry sample fixation2% paraformaldehyde before analysis
Biological safety cabinet classProperly maintained BSCs (preferably Class II)

Frequently asked questions

What must a lab member do before working in the Weber lab?

Each lab member must read the manual, discuss it with Dr. Weber, and get his signature as a prerequisite for working in the laboratory.

Who will not work on the Listeria monocytogenes project?

Pregnant women, the elderly, and immune-compromised individuals are excluded from this project as a precaution.

Where must all of the BSL-2 work be done?

All BSL-2 work must be done in room 3126A LSB or the mouse room 1012B LSB.

How are gloves and labcoats handled when working with Listeria monocytogenes?

Gloves and labcoats must be worn, and hands must be washed with soap after working with Listeria monocytogenes and before leaving the room.