Yokohama City Manual for Creating Evacuation and Flood Prevention Plans for Underground Streets

This document introduces the risk of flooding in underground streets and other places, and provides preventive and countermeasures.


Yokohama City Manual for Creating Evacuation and Flood Prevention Plans for Underground Streets - cover page
Brand
Yokohama City
Document type
Other
Language
Japanese
Pages
47
File format
PDF
File size
1.6 MB
Published
15 November, 2023
Updated
15 November, 2023
MD5 checksum
8593308DC6D5310806C716A34C61B1A6

About this manual

This manual, issued by the General Affairs Bureau of Yokohama City (July 2016, revised February 2022), explains how the owners or administrators of underground streets in the city prepare an evacuation and flood prevention plan under the Flood Prevention Act. It presents flood damage examples, including the October 2004 Typhoon No. 22 at the west exit of Yokohama Station, the dangers of flooding in underground spaces, and the particular characteristics of evacuation from them.

The manual then covers building an organization to respond to flooding, collecting and transmitting information, setting up a self-defense flood prevention organization, and conducting drills (map exercises and field drills). It gives the procedure for drafting the plan with sample forms and attachments such as contact networks and evacuation route maps, and explains how the plan is reported and made public, followed by reference materials including the Fire Service Act enforcement order table and the report form. This manual is written in Japanese.

What's inside

  • Introduction
  • Flood risk in underground streets and case examples
  • Need to create an evacuation and flood prevention plan
  • Scope of underground streets
  • Establishing a system to prepare for flood damage
  • Collecting and transmitting information
  • Setting up a self-defense flood prevention organization
  • Establishing an activity system
  • Disaster prevention drills
  • Creating, reporting and publishing the plan

Frequently asked questions

Who prepares the evacuation and flood prevention plan?

The owner or administrator of the underground street prepares it, either alone or jointly with others.

Which law requires the plan?

The Flood Prevention Act, Article 15-2, requires owners or administrators of underground streets in flood-inundation assumed areas to prepare the plan.

At what water depth can doors no longer be opened?

At a water depth of roughly 30 to 50 cm, water pressure prevents doors from being opened or closed, whether they open inward or outward.

What did the 2013 amendment of the Flood Prevention Act add?

It newly made the preparation of a flood prevention plan, the carrying out of drills and the establishment of a self-defense flood prevention organization mandatory.