Aosaike ZC Series Column Ultrafiltration Membrane Assembly Product Technical Manual

This document describes the technical parameters and performance characteristics of ZC series column ultrafiltration membrane components.


Aosaike ZC Series Column Ultrafiltration Membrane Assembly Product Technical Manual - cover page
Brand
奥赛科
Category
Other
Document type
User Manual
Language
Chinese
Pages
35
File format
PDF
File size
1.7 MB
Published
15 November, 2023
Updated
15 November, 2023
MD5 checksum
5E3577C2C4F53E930581E844BE85D59E

About this manual

This 2023 product technical manual from Aosaike Membrane Technology (Tianjin) Co., Ltd. covers the ZC series column ultrafiltration membrane modules. Its chapters introduce ultrafiltration, describe ZC hollow-fiber module features, model and specification tables, design guidelines, operating procedures, service conditions, cleaning, installation, operation, integrity testing, repair, transport and storage, and limited warranty terms.

The manual states that ZC modules use PVDF membrane filaments, epoxy potting, and UPVC membrane housings. It lists ZC-8051 and ZC-8080 models with 51 m² and 80 m² membrane areas, a nominal pore size of 0.02 μm, maximum feed turbidity of 300 NTU, maximum feed pressure of 0.30 MPa, maximum operating temperature of 40°C, and pH tolerance of 2–12. This manual is written in Chinese.

What's inside

  • Ultrafiltration introduction
  • ZC hollow fiber ultrafiltration membrane module
  • Product features
  • Model and specification description
  • Design guidelines for ZC membrane modules
  • Operating procedures
  • Service conditions
  • Cleaning
  • Installation guide
  • Operation guide

Specifications

Nominal membrane pore size0.02 μm
Membrane area (ZC-8051 / ZC-8080)51 m² / 80 m²
Membrane filament materialPVDF
Potting materialEpoxy resin
Membrane housing materialUPVC
Maximum feed turbidity300 NTU
Maximum feed pressure0.30 MPa
Maximum operating temperature40 °C
pH tolerance range2–12
Membrane filament inner/outer diameter0.7/1.3 mm

Frequently asked questions

What membrane material do ZC modules use?

The membrane filaments are made of polyvinylidene fluoride (PVDF).

What is the nominal membrane pore size?

The nominal membrane pore size is 0.02 μm.

What are the maximum feed pressure and operating temperature?

The maximum feed pressure is 0.30 MPa and the maximum operating temperature is 40°C.

What initial permeate flow is recommended for first operation?

For initial operation, the manual recommends manual startup with permeate flow set to 60% of design permeate flow.