INTERTEC CP SLIMTHERM DC.A Heater Operating Instructions

This operating manual describes how to operate the CP..THERM heater safely and correctly. The heater complies with the standards GB 3836.13-2013, GB 3836.15-2000, GB 3836.16-2006, GB 50257-2014, GB 12476.2-2010, GB 15577-2007 and is suitable for direct heating via flange connection (heat conduction) or for indoor heating (air convection).


INTERTEC CP SLIMTHERM DC.A Heater Operating Instructions - cover page
Brand
INTERTEC
Category
Heater
Document type
User Manual
Language
Chinese
Pages
11
File format
PDF
File size
9.7 MB
Published
15 November, 2023
Updated
15 November, 2023
MD5 checksum
7B88942D6915AFA5A8C23CCDBC7D2A82

About this manual

The INTERTEC CP SLIMTHERM DC.A is a heater from INTERTEC-Hess GmbH intended for direct heating by flange connection (heat conduction) or room heating by air convection. It is described for use in explosive gas and dust environments, zone 1 and 2, temperature classes T3 to T6, with applications including frost protection, prevention of condensation and maintaining temperature.

The manual covers special conditions for safe use, safety notices, technical data, installation, electrical connection, commissioning, maintenance, troubleshooting, dismantling, disposal, the declaration of conformity and certification. Technical data include IP66/IP68 protection, a measuring voltage of max 250 V AC, a permissible operating voltage of max 275 V AC, a rated current of max 10 A, and an ambient temperature range of -60 to +80 °C. This manual is written in Chinese.

What's inside

  • Overview
  • Application
  • Special conditions for safe use
  • Safety notices and warning symbols
  • Technical data
  • Installation
  • Connection
  • Commissioning
  • Maintenance
  • Troubleshooting

Specifications

Protection classIP66/IP68 1 bar/30 min
Measuring voltageMax 250 V AC
Permissible operating voltageMax 275 V AC
Ambient temperature-60 to +80 °C
Maximum application temperature-60 to +180 °C
MaterialAluminum, seawater-resistant, black anodized
Mean time before failure50,000 h
Profile size L (H x W x D)105 x 206 x 30 mm
Profile size P (H x W x D)225 x 206 x 30 mm
Profile size T (H x W x D)325 x 206 x 30 mm

Frequently asked questions

What applications is the heater suitable for?

The manual lists frost protection, prevention of condensation and maintaining temperature.

What is the protection class of the CP SLIMTHERM DC.A?

The stated protection class is IP66/IP68, 1 bar/30 min.

What maintenance does the heater require?

The manual states that no maintenance is required due to the device design; function and safety test intervals can be set by agreement with the operator.

What should be done if the high-temperature indicator turns black?

If more than four fields turn black, the heater must be dismantled and returned to the manufacturer for inspection.